![Ingeteam INGEREV RAPID ST Series Installation And Operation Manual Download Page 21](http://html1.mh-extra.com/html/ingeteam/ingerev-rapid-st-series/ingerev-rapid-st-series_installation-and-operation-manual_2060703021.webp)
ABX2011IQM01_ - Installation and Operation Manual
2.13. Specification table
INGEREV RAPID ST200
INGEREV RAPID ST400
AC input (auxiliary services)
Voltage
380 ~ 440 V
Frequency
50/60 Hz
Rated current
6 A
Rated power
3 kW
DC input (power)
Voltage
575 ~ 750 V
Rated current
300 A
600 A
DC output
Voltage range
50 ~ 920 V
Maximum current
300 A
500 A
Maximum power
180 kW
360 kW
Charging connectors
One: CCS Tipo 2
Duo: CCS Tipo 2 + CHAdeMO
Duo: CCS Tipo 2 + CHAdeMO
Duo: CCS Tipo 2 + CCS Tipo 2
Regulations and safety compliance
Standards
IEC 61851-1, IEC 61851-23, IEC 61851-24, CHAdeMO 1.0.0, DIN 70121,
ISO 15118, IEC 61000
Overcurrent protection
16 A circuit breaker Curve C in auxiliary circuit
Protection against indirect contacts
Differential 16 A 30 mA Type B
Overvoltage protection
Type III surge arrester
General information
Cooling system
Integrated liquid cooling with heat evacuation to the outside environment
Stand-by consumption
< 100 W
Operating temperature
-25 ºC ~ 60 ºC
Humidity
0 ~ 95% (without condensation)
Weight
560
kg
460
kg
Dimensions (Width x Depth x Height)
774 x 904 x 2547 mm (including hose guide ring)
Protection class
IP54 / IK10 (IK08 for display and vents)
Markings
CE
Maximum altitude
Up to 2000 m
21
Unit description
Ingeteam