Book 35393065 (7/02)
31
( )
Hose Reel Operation
To Unwind Hose
1. Disconnect end of hose from docking port at bottom
right--hand corner of compressor.
2. Release reel lock pin on left--hand side of reel by
pulling and rotating pin toward cradle and releasing it.
3. Pull hose to unwind.
4. Re--engage reel lock pin into reel.
To Retract Hose
1. Release reel lock pin on left--hand side of reel, by
pulling and rotating pin toward cradle and releasing it.
2. Push and hold in “Reel Rewind” button at bottom
right--hand corner of compressor.
WARNING: Keep Hands AWAY from Hose Reel
while controlling hose.
3. Secure end of hose into docking port.
4. Reengage reel lock pin into reel.
To Swing Hose Reel Away from Compressor Door
1. Disconnect end of hose from docking port at bottom
right--hand corner of compressor.
2. Release latch on right--side of hose reel frame.
3. Swing hose reel out, away from compressor door.
CAUTION: Hose Reel Must Be Returned To It’s
Latched Position Before Moving Vehicle.
OPERATION OF OPTIONAL GENERATOR
This unit will operate in three modes, depending on the
position of the generator control switch (located on the
front of the generator control panel).
S
In “Generator” position, the engine will maintain idle
speed, and the generator will give a constant voltage
and frequency output, for use with sensitive
equipment like computers, fusion welders, etc. No
compressed air is available at the service air valves in
this mode.
S
In “Gen/Air” position, voltage and frequency will vary
as engine speed changes to meet air demands, and
should only be used for lights and hand tools.
S
In “Air” position, the generator provides no electrical
power.
1.
Start compressor with the Start--Run Switch
located in the bottom right corner of the instrument
panel) in the “Start/Warm--up” position.
2.
Close all service air valves.
3.
Place the start--run switch in the “Run” position.
4.
Place the generator control switch in either
“Generator” or “Gen/Air” position. The red light on the
front of the generator control panel should glow, and
the voltage meter should read 120 Volts AC.
5.
Plug electric tools or lights into the receptacles on
the front of the generator control panel.