![Ingersoll-Rand Odyssey TTA061G A Series Installation, Operation And Maintenance Manual Download Page 51](http://html1.mh-extra.com/html/ingersoll-rand/odyssey-tta061g-a-series/odyssey-tta061g-a-series_installation-operation-and-maintenance-manual_2059234051.webp)
SS-SVX10H-EN
51
Maintenance
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
us
s V
Vo
olltta
ag
ge
e w
w//C
Ca
ap
pa
ac
ciitto
orrs
s!!
F
Fa
aiillu
urre
e tto
o d
diissc
co
on
nn
ne
ecctt p
po
ow
we
err a
an
nd
d d
diisscch
ha
arrg
ge
e
c
ca
ap
pa
acciitto
orrss b
be
effo
orre
e s
se
errv
viic
ciin
ng
g c
co
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
s
se
erriio
ou
us
s iin
njju
urry
y..
D
Diisscco
on
nn
ne
ec
ctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diis
scco
on
nn
ne
eccttss a
an
nd
d d
diisscch
ha
arrg
ge
e a
allll m
mo
otto
orr sstta
arrtt//rru
un
n
c
ca
ap
pa
acciitto
orrss b
be
effo
orre
e s
se
errv
viic
ciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err llo
occkko
ou
utt//
tta
ag
go
ou
utt p
prro
oc
ce
ed
du
urre
es
s tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err cca
an
nn
no
ott b
be
e
iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. F
Fo
orr v
va
arriia
ab
blle
e ffrre
eq
qu
ue
en
nccy
y
d
drriiv
ve
ess o
orr o
otth
he
err e
en
ne
errg
gy
y sstto
orriin
ng
g cco
om
mp
po
on
ne
en
ntts
s
p
prro
ov
viid
de
ed
d b
by
y T
Trra
an
ne
e o
orr o
otth
he
errss,, rre
effe
err tto
o tth
he
e
a
ap
pp
prro
op
prriia
atte
e m
ma
an
nu
uffa
ac
cttu
urre
err’’s
s lliitte
erra
attu
urre
e ffo
orr
a
allllo
ow
wa
ab
blle
e w
wa
aiittiin
ng
g p
pe
erriio
od
dss ffo
orr d
diis
sc
ch
ha
arrg
ge
e o
off
c
ca
ap
pa
acciitto
orrss.. V
Ve
erriiffy
y w
wiitth
h a
an
n a
ap
pp
prro
op
prriia
atte
e v
vo
ollttm
me
ette
err
tth
ha
att a
allll c
ca
ap
pa
acciitto
orrss h
ha
av
ve
e d
diisscch
ha
arrg
ge
ed
d..
F
Fo
orr a
ad
dd
diittiio
on
na
all iin
nffo
orrm
ma
attiio
on
n rre
eg
ga
arrd
diin
ng
g tth
he
e ssa
affe
e
d
diis
scch
ha
arrg
ge
e o
off c
ca
ap
pa
acciitto
orrss,, sse
ee
e P
PR
RO
OD
D--S
SV
VB
B0
06
6*
*--E
EN
N..
N
NO
OT
TIIC
CE
E
O
Op
pe
erra
attiin
ng
g U
Un
nd
de
err V
Va
ac
cu
uu
um
m!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w tth
he
es
se
e iin
ns
sttrru
uccttiio
on
nss w
wiillll rre
essu
ulltt iin
n
c
co
om
mp
prre
esssso
orr ffa
aiillu
urre
e..
D
Do
o n
no
ott o
op
pe
erra
atte
e o
orr a
ap
pp
plly
y p
po
ow
we
err tto
o tth
he
e cco
om
mp
prre
esssso
orr
w
wh
hiille
e u
un
nd
de
err a
a v
va
accu
uu
um
m..
Perform all of the indicated maintenance procedures at
the intervals scheduled. This will prolong the life of the
unit and reduce the possibility of costly equipment
failure.
Monthly
Conduct the following maintenance inspections once
per month.
Check unit wiring to ensure all connections are tight
and that the wiring insulation is intact.
Inspect the condenser coils for dirt and debris. If the
coils appear dirty, clean them.
With the unit operating in the cooling mode, check
the suction and discharge pressures and compare
them with Pressure Curve values in unit Service
Facts. Record these readings on the
.
Annually (Cooling Season)
The following maintenance procedures must be
performed at the beginning of each cooling season to
ensure efficient unit operation.
Perform all of the monthly maintenance
inspections.
With the unit operating, check unit superheat and
record the reading in the
Remove any accumulation of dust and/or dirt from
the unit casing.
Remove corrosion from any surface and repaint.
Check the gasket around the control panel door to
ensure it fits correctly and is in good condition to
prevent water leakage.
Inspect the control panel wiring to ensure that all
connections are tight and that the insulation is
intact.
N
No
otte
e:: Condenser fan motors are permanently
lubricated.
Check refrigerant piping and fittings for leaks
Inspect the condenser coils for dirt and debris. If the
coils appear dirty, clean them.
Coil Cleaning
Regular coil maintenance, including annual cleaning-
enhances the unit's operating efficiency by minimizing:
•
compressor head pressure and amperage draw
•
water carryover
•
fan brake horsepower
•
static pressure losses
At least once each year — or more often if the unit is
located in a “dirty” environment — clean the coil using
the instructions outlined below. Be sure to follow these
instructions as closely as possible to avoid damaging
the coils.
Microchannel (MCHE) Coils
N
NO
OT
TIIC
CE
E
C
Co
oiill D
Da
am
ma
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
ns
sttrru
uc
cttiio
on
nss b
be
ello
ow
w cco
ou
ulld
d rre
essu
ulltt iin
n
cco
oiill d
da
am
ma
ag
ge
e..
D
DO
O N
NO
OT
T u
usse
e a
an
ny
y d
de
ette
errg
ge
en
nttss w
wiitth
h m
miiccrro
occh
ha
an
nn
ne
ell
cco
on
nd
de
en
nsse
err cco
oiills
s..
U
Usse
e p
prre
essssu
urriizze
ed
d w
wa
atte
err o
orr a
aiirr O
ON
NL
LY
Y,, w
wiitth
h p
prre
essssu
urre
e
n
no
o g
grre
ea
atte
err tth
ha
an
n 6
60
00
0p
pssii..
F
Fo
orr a
ad
dd
diittiio
on
na
all iin
nffo
orrm
ma
attiio
on
n rre
eg
ga
arrd
diin
ng
g tth
he
e p
prro
op
pe
err
m
miiccrro
occh
ha
an
nn
ne
ell cco
oiill cclle
ea
an
niin
ng
g p
prro
occe
ed
du
urre
e,, rre
effe
err tto
o R
RT
T--
S
SV
VB
B8
83
3*
*--E
EN
N
Due to the soft material and thin walls of the MCHE
coils, the traditional field maintenance method
recommended for Round Tube Plate Fin (RTPF) coils
does not apply to microchannel coils. Moreover,
chemical cleaners are a risk factor to MCHE due to the
material of the coil. The manufacturer does not
recommend the use of chemical cleaners to clean
microchannel coils. Using chemical cleaners could lead
to warranty claims being further evaluated for validity
and failure analysis.