![Ingersoll-Rand EP 60 Operators/Instruction Manual Options Download Page 34](http://html1.mh-extra.com/html/ingersoll-rand/ep-60/ep-60_operators-instruction-manual-options_2059129034.webp)
32
5.6 COOLANT
■
SSR Ultra Coolant (Standard Factory Fill)
■
SSR H1-F Food Grade (Optional)
SSR Ultra Coolant is a polyglycol base coolant. Change
Ultra Coolant after every 8000 hours or every two years,
whichever comes first.
SSR Food Grade Coolant is a polyalphaolefin base
coolant. Change after every 1000 hours or every 6
months whichever comes first. Do not operate unit
beyond this 1000 hour coolant change interval, as
coolant degradation will occur.
Items Required
In addition to the tools normally found in any reasonably
equipped serviceman’s toolbox, the following items
should be available at the work site:
1) Suitable drain pan and container to hold lubricant
drained from unit.
2) A quantity of proper lubricant sufficient to refill the
compressor.
3)
A minimum of one replacement coolant filter element
of the proper type for the unit to be worked on.
There is a coolant drain hose supplied with each
compressor. The drain hose is placed in the starter box
when shipped from the factory.
The coolant should be drained soon after the compressor
has been shut down. When the coolant is hot, drainage
will be more complete and any particles in suspension in
the coolant will be carried out with the coolant.
Hot coolant can cause severe injury. Use care when
draining separator tank.
To drain the unit, remove plug from drain valve located on
the bottom of the separator tank. Install supplied drain
hose and fitting assembly in end of drain valve and place
end of hose in a suitable pan. Open drain valve to start
drainage. After draining is complete, close valve, remove
hose and fitting assembly from valve, and store in a
suitable location for future use. Replace plug in end of
drain valve.
Do not store drain hose in starter box after it has
been used to drain the separator tank.
50 hp (37 kw).....................5.0 gallons (19.0 liters)
60 hp (45 kw).....................5.0 gallons (19.0 liters)
75/100 hp (55-75 kw) ........9.0 gallons (34.2 liters)
Coolant fill quantity
WARNING
!
Hot coolant can cause severe injury.
Use care when near this area.
Ingersoll-Rand
Rotary-Recip Compressor Division
Davidson, NC
NOTICE
Filler Cap.
Use only recommended
coolant.
Read instruction book before
servicing.
Rotary-Recip
Compressor Division
Davidson, NC
Summary of Contents for EP 60
Page 18: ...16 FIGURE 2 5 1 TYPICAL OUTDOOR SHELTERED INSTALLATION ...
Page 31: ...29 NOTES ...
Page 44: ...42 7 0 REFERENCE DRAWINGS 7 1 ELECTRICAL SCHEMATIC FULL VOLTAGE 39899794 REV 02 ...
Page 45: ...43 7 2 ELECTRICAL SCHEMATIC STAR DELTA 39899786 REV 02 ...
Page 46: ...44 7 3 FOUNDATION PLAN AIR COOLED 39894472 REV 03 ...
Page 47: ...45 7 4 FOUNDATION PLAN WATER COOLED 39907894 REV 03 ...
Page 48: ...46 7 5 FOUNDATION PLAN OUTDOOR MOD 39907886 REV 03 ...
Page 49: ...7 6 BASIC FLOW SCHEMATIC AIR COOLED 39899828 REV 02 47 ...
Page 50: ...48 7 7 BASIC FLOW SCHEMATIC WATER COOLED 39899836 REV 02 ...
Page 51: ...49 7 8 TYPICAL SYSTEM FLOW DIAGRAMS TYPICAL SYSTEM FLOW DIAGRAM ...
Page 52: ...50 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 53: ...51 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 54: ...52 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 55: ...53 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 59: ...57 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY 9 0 MAINTENANCE RECORD ...
Page 60: ...DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD 58 ...
Page 61: ...59 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...
Page 62: ...60 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...