3.4 PUSH BUTTONS (Continued)
DISPLAY SELECT
Pressing this button will change the information
selected for the display. The display table will be
incremented. If the button is held, this display table
will scroll. This button can also be used to exit the
set point procedure.
NOTE: For readings less than 1 hr., hourmeter
displays minutes. After 1 hr. the hourmeter displays
hours.
SET
The SET button is used to enter the set point
procedure. The set button is also used to reset
warnings and alarms. Pressing this button once will
reset a warning, twice will clear an alarm.
ARROWS
These buttons have several functions. If the
Intellisys is in the set point mode, the ARROWS are
used to change the set point values. If the unit has
multiple alarms or warnings, the ARROWS are used
to scroll through these conditions. The ARROWS
have a function in the calibration routine, which will
be described later.
PRESSURE SENSOR CALIBRATION (ZEROING)
ROUTINE
This routine is entered if the unit is not running and
both the up and down arrows button are pressed at
the same time. Make sure all pressure is relieved
from the compressor before calibration. The display
will flash the message “CALIBRATING”. After
calibration is completed the display will indicate
“READY TO START”. Zeroing should only be done
after a pressure sensor has been replaced or any
controller change.
DISPLAY
SELECT
SET
Summary of Contents for EP 60
Page 18: ...16 FIGURE 2 5 1 TYPICAL OUTDOOR SHELTERED INSTALLATION ...
Page 31: ...29 NOTES ...
Page 44: ...42 7 0 REFERENCE DRAWINGS 7 1 ELECTRICAL SCHEMATIC FULL VOLTAGE 39899794 REV 02 ...
Page 45: ...43 7 2 ELECTRICAL SCHEMATIC STAR DELTA 39899786 REV 02 ...
Page 46: ...44 7 3 FOUNDATION PLAN AIR COOLED 39894472 REV 03 ...
Page 47: ...45 7 4 FOUNDATION PLAN WATER COOLED 39907894 REV 03 ...
Page 48: ...46 7 5 FOUNDATION PLAN OUTDOOR MOD 39907886 REV 03 ...
Page 49: ...7 6 BASIC FLOW SCHEMATIC AIR COOLED 39899828 REV 02 47 ...
Page 50: ...48 7 7 BASIC FLOW SCHEMATIC WATER COOLED 39899836 REV 02 ...
Page 51: ...49 7 8 TYPICAL SYSTEM FLOW DIAGRAMS TYPICAL SYSTEM FLOW DIAGRAM ...
Page 52: ...50 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 53: ...51 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 54: ...52 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 55: ...53 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 59: ...57 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY 9 0 MAINTENANCE RECORD ...
Page 60: ...DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD 58 ...
Page 61: ...59 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...
Page 62: ...60 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...