14
Albinpump.com
Albin Pump ALP Instruction Manual
since 1928
ALP
Maintenance / Storage
6 .4 - MAINTENANCE AND PERIODIC INSPECTIONS ALP SERIES
1
Pump hose replacement.
In prevention, change the pump hose after
90 % of the life time of the first hose.
see §6.2
2
Gearbox oil replacement.
Refer to the gearbox maintenance manual
provided with the pump.
3
Replacement of the rollers.
The contact surface of a roller should
be flat. Replace if the contact surface is
concave.
4
Check for wear on the roller pressing surface.
At every hose change.
5
Check the presence of a gearbox oil leakage.
Before starting the pump and periodically
during the pump service.
6
Check for strange noises coming from the
pump, gearbox and bearing case or abnormal
pump casing temperature.
Periodically during the pump service.
7
Check for leakages at inlet and outlet ports.
Periodically during the pump service.
Re-tighten collars.
7
| STORAGE
7 .1 - STORAGE OF THE PUMP
Store the pump in a sheltered and dry place and ensure that the storage room temperature is between
-20°C (-4°F) and 55°C (131°F).
Protect the pump if necessary and block the inlet and outlet orifices:
If the pump stays without working more than 1 month, withdraw the hose from the pump or withdraw one
of the rollers from the hose.
If you can neither withdraw the hose or one of the rollers, run the pump 5min a week.
7 .2 - STORAGE OF THE HOSE PUMP
Hoses must be stored sheltered from light in a cool place. The hose life is reduced after two years. The
performance of hoses is reduced at the end of this expiry date due to the ageing of rubber.