Gas corresponding to the category. 

 

Pressure regarding the gas. 

 

Nominal consumption Q

n

(H

i

). 

 

Flow. 

On the other hand, it is very important that the installer knows the gas supply characteristics where 
the appliance is to be installed by consulting the supply company and checking that the appliance 
is prepared for such installation. 

C O N N EC T I N G   T H E  A P PL I AN C E   T O   T H E   M AI N   G AS   S U P P L Y  

Once the gas dates has been checked, the installer can connect the appliance to the main gas 
supply, according to the regulation in force in the destined country. The grill has been 
manufactured to be used with the gas of community destined countries. The flexible tube from the 
main supply to the appliance inlet must fulfill the national requirement in force and must be 
checked periodically and replace it when it will be necessary. 
The griddles have the gas inlet 1/2” placed in the left side. 

P ER F O R M AN C E  C O N T R O L    

·The appliance has the necessary instructions for your use  
· Control the gas escapes of the appliances. 
· Check the ignition and the main burner flame. 
· We recommend the user to use the appliance as the instructions. 

C O N N EC T I O N   F O R   T H E   R EM O V AL   O F   V A PO U R S  

As the removal method, there are appliances of 

A

1

 type, defined as appliances without ventilator 

not destined to connect to any conduct, neither a removal combustion products dispositive to the 
outside where are installed. These appliances will be installed with an enough ventilation to 
prevent the non admissible concentration of harmful substance for the health in the local where be 
installed as recommend in the installations instructions manual. 
The appliance must be installed under extractor hood to secure the complete gas combustion and 
burners fumes evacuation in cooking phase, avoiding the concentrations of the fumes and 
combustion gases.

 

I N ST R U C T I O N S   F O R   C O N V E R S I O N   T O   O T H E R   G AS   T Y P ES  

IMPORTANT: 

The conversion of the appliance to different gases or feed pressures must be 

carried out by personnel authorized by the legislation in force in the destined country.  
All the appliances are subjected to trials and tests, each one independently and are adjusted to the 
gas type indicated on the labels on the appliance and packaging. 
In the case that it is necessary to adapt the appliance to another gas type, the enclose kit comprising 
of the necessary injector for each gas type must be inspected and the instructions manual followed 
to install the suitable injector for the appliance and it must reflect this change. 
For the conversion to a different gas type must be replace the injector in the burners. 

I N J EC T O R   R E PL AC E M EN T  

For easy access to the injector and venturi burner, it is only necessary to remove the top plate.To 
proceed to the change of injectors according to the gas to be used will take into account the values 
of the injector diameters indicated in the technical date table. 
Once the injector holder from the set of gas is removed, withdraws the injector and placed the new. 
This operation will take place for all burners available to the 
appliance. 

F L O W   P R I M AR Y   AI R   AD J U ST EM E N T   F O R   C O M B U ST I O N    

The manufacturer gives the appliance with the air adjustment to the 
requested gas. 

Summary of Contents for PG-60PV

Page 1: ...PG 60PV PG 75PV PG 90PV Versi n Categor a ll2H3 Category Version Tipo de instalaci n A1 Instalation type Ed Rev 1 Leer atentamente el presente manual antes de instalar y utilizar el aparato Conservar...

Page 2: ...ominaci n PLANCHAS DE GAS PARA USO COLECTIVO Marca Serie PG Modelos PG 60PV PG 75PV PG 90PV objeto de esta declaraci n es conforme con el modelo descrito en el Certificado de Examen CE de Tipo n emiti...

Page 3: ...30 30 4 1 2 63 4 2 2 31 1 00 2 5 G31 30 4 1 2 63 4 2 2 31 1 00 2 5 G30 50 4 2 2 7 4 3 2 36 0 90 2 5 G31 50 4 2 2 7 4 4 2 42 0 90 2 5 Modelo Dimensiones mm ancho x largo x alto N quemadores Qn Hi kW G2...

Page 4: ...y que debido al transporte no han sufrido desajustes El aparato debe estar instalado a una distancia m nima de 200 mm de cualquier pared lateral y trasera para proteger de las temperaturas pr ximas a...

Page 5: ...djunto que va compuesto de los inyectores necesarios para cada tipo de gas siguiendo el presente libro de instrucciones a fin de colocar el inyector adecuado y se alado al efecto Para la conversi n a...

Page 6: ...manipularse por el instalador y el usuario Para realizar el mantenimiento limpieza o reparaciones se debe cerrar la llave del gas La modificaci n eliminaci n o falta de mantenimiento de cualquier disp...

Page 7: ...la m quina Proceder a la limpieza de la parte de acero con agua tibia y con jab n enjuague y seque bien No usar detergentes con cloro lej a cido clorh drico etc Evitar la limpieza del acero con copos...

Page 8: ...e mbar Qn Hi kW Serie ECO PV ECO ES Qn Hi kW Serie ECO CD Injector Diameter mm Air regulation A mm Nominal Minimum Nominal Minimum G20 20 4 1 2 63 4 0 2 2 1 45 1 5 G25 25 4 1 2 63 4 0 2 2 1 45 1 5 G30...

Page 9: ...lled on non flammable surfaces The appliance must be installed at least 1 5 m distant from any other flammable material The parts that have been protected by the manufacturer MUST NOT BE MANIPULATED b...

Page 10: ...ration of harmful substance for the health in the local where be installed as recommend in the installations instructions manual The appliance must be installed under extractor hood to secure the comp...

Page 11: ...appliances in Kilowatt KW L unit air evacuation flow 10m3 h Kw CARACTERISTICHS PLATE The caracteristichs plate is placed in the back part LUBRICATE VALVES Not lubricate the valve in any case if it doe...

Page 12: ...rinse and dry thoroughly Do not use detergent with chorine bleach acid HCL etc Avoid cleaning of steel with flakes or brushes that could cause grated Clean the removable part of the burner of the sto...

Reviews: