REPLACEMENT ELEMENT INSTALLATION 

(VISIT INFRATECH-USA.COM FOR VIDEO INSTRUCTIONS)

Disconnect the power at the breaker. Remove the grill by grasping it in the middle, flex grill up and lift it off. Unscrew 
and remove both end reflectors. Unhook element clips at each end of the heater and remove nuts from end of element 
to remove the existing quartz tube. Carefully install the new element. Remove one nut from end of the new element. 
Install wire by sliding high temperature ring terminal onto element screw and replace nut. Use a thin 11/32" wrench to 
hold inside nut. Nuts must make a tight connection. Close element clips over tube, reinstall end reflectors, then snap 
protective grill back in place.

NOTE:  Hold ceramic element firmly while 

tightening nut to prevent damage to 
element. Nut should be tightened snug.  
A loose connection can cause the  
element to short or fail prematurely.

SCAN FOR 

VIDEO 

INSTRUCTIONS

Need help? 

To order replacement 

elements for your Infratech 

heating system, please contact  

us via phone or visit our website.

Consult the  label on back of 

heater for proper watts, voltage, 

and replacement element part 

number.

REPLACEMENT ELEMENTS 

(OTHER VOLTAGES ALSO AVAILABLE)

 

PART NUMBER 

ELEMENT NUMBER 

LENGTH 

WATTS 

VOLTS 

FITS

 

10-1020 

E-7512  16-1/2" 

(0.4m) 

750 120 C-7512

  10-1050 

E-1412 

30" (0.8m) 

1500 

120 

C-1512

  10-1055 

E-1424 

30" (0.8m) 

1500 

240 

C-1524/CD-3024

  10-1085 

E-2024 

36" (0.9m) 

2000 

240 

C-2024/CD-4024

  10-2010 

E-2524 

36" (0.9m) 

2500 

240 

C-2524/CD-5024

  10-2030 

E-3024 

58" (1.5m) 

3000 

240 

C-3024/CD-6024

  10-2055 

E-4024 

58" (1.5m) 

4000 

240 

C-4024

REPLACEMENT PARTS

  PART NUMBER 

PART DESCRIPTION 

QUANTITY

 

13-1210 

Single Element End Reflector (Set of 2) 

1

  13-1252 

Dual Element End Reflector (Set of 2) 

1

  13-1207, 13-1208, 13-1209 

C-Series Body Reflector – Fits 33" (0.8m), 39" (1.0m), 61-1/4" (1.6m) 

1

  13-1242, 13-1240, 13-1245 

Grill Guard – Fits 33" (0.8m), 39" (1.0m), 61-1/4" (1.6m) 

1

  13-1232, 13-1230, 13-1235 

Lead Wire Set – Fits 33" (0.8m), 39" (1.0m), 61-1/4" (1.6m)* 

1

  13-1250 

SS Mounting Bracket (Set of 2) 

1

* Note: Dual Element Heaters require 2 Lead Wire Sets per Heater

11/32" OUTSIDE NUT

11/32" INSIDE NUT 
(SNUG TO CERAMIC)

Summary of Contents for C Series

Page 1: ...VE THIS MANUAL FOR FUTURE REFERENCE TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance Instructions 6 Trouble Shooting 7 Location Suggestions 7 Warranty 8 ...

Page 2: ...d as UL CUL Listed from floor while heater is set at a downward angle of 30 to 60 degrees For Ceiling Mounting do not install heater closer than 18 45 7cm from adjacent walls and 6 15 2cm from ceiling and do not install less than 6 1 8m if the heater is labeled as UL Listed and 8 2 4m if the heater is labeled as UL CUL Listed from floor while heater is at a maximum 30 degrees Adjacent Heaters to b...

Page 3: ...allic flexible or liquid tight conduit for the installation location Observe local electrical code regulations Remove cover plate from junction box Attach conduit Use only copper wire suitable for 90 C Replace cover plate Connect power with flexible conduit or appropriate cord to allow heater to be swiveled Junction Box on top of the heater has a gasket side access cover The Junction Box inlet hol...

Page 4: ...inimum clearance is maintained around the heater on all four sides and 36 91 4cm directly in front A minimum of 6 15 24cm of clearance provided by mounting brackets is required behind the plane of the face Heater can be hung using chains or custom brackets Heater must be level but can be rotated around its horizontal axis Heater must be installed with the quartz tube horizontally level For maximum...

Page 5: ...eplacement elements for your Infratech heatingsystem pleasecontact usviaphoneorvisitourwebsite Consultthe labelonbackof heaterforproperwatts voltage andreplacementelementpart number REPLACEMENT ELEMENTS OTHER VOLTAGES ALSO AVAILABLE PART NUMBER ELEMENT NUMBER LENGTH WATTS VOLTS FITS 10 1020 E 7512 16 1 2 0 4m 750 120 C 7512 10 1050 E 1412 30 0 8m 1500 120 C 1512 10 1055 E 1424 30 0 8m 1500 240 C 1...

Page 6: ...egulator This low cost controller which is actually an infinite switch gently pulses the heat on and off at regular intervals when not on full power Dual Element Heaters can be wired with our Duplex Stack Switch which enables the ability to turn on and off each element independently providing for half power full power capabilities For ideal comfort heat the best solution is to heat from two sides ...

Page 7: ...TING Unless heaters are installed over 12 3 7m high it is generally recommended that all radiant heaters be mounted on an angle to assure that radiant warmth is distributed from the sides rather than straight down on the heads and shoulders of the people being warmed LOCATION SUGGESTIONS Angle fixture 30º to 60º from horizontal face down Best angle is approximately 45º Install fixture to heat the ...

Page 8: ... is not responsible for consequential or incidental damages Under no circumstances shall INFRATECH or any of its representatives be held liable for injury to any person or damage to any property however arising Important Please retain original proof of purchase to establish warranty period Any implied warranties of merchantability and fitness applicable to the equipment are limited in duration to ...

Reviews: