INSTALLATION USE & CARE MANUAL

ALL WEATHER C-SERIES AND CD-SERIES
QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

SAVE THIS MANUAL FOR FUTURE REFERENCE

TABLE OF CONTENTS

Warnings 2

Installation Instructions 

Wiring Instructions  

3

Mounting Instructions 

4

Replacement Element Installation 

5

Replacement Parts 

5

Heater Coverage Areas 

6

General Notes 

6

Maintenance Instructions 

6

Trouble Shooting 

7

Location Suggestions 

7

Warranty 8

Summary of Contents for C Series

Page 1: ...VE THIS MANUAL FOR FUTURE REFERENCE TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance Instructions 6 Trouble Shooting 7 Location Suggestions 7 Warranty 8 ...

Page 2: ...d as UL CUL Listed from floor while heater is set at a downward angle of 30 to 60 degrees For Ceiling Mounting do not install heater closer than 18 45 7cm from adjacent walls and 6 15 2cm from ceiling and do not install less than 6 1 8m if the heater is labeled as UL Listed and 8 2 4m if the heater is labeled as UL CUL Listed from floor while heater is at a maximum 30 degrees Adjacent Heaters to b...

Page 3: ...allic flexible or liquid tight conduit for the installation location Observe local electrical code regulations Remove cover plate from junction box Attach conduit Use only copper wire suitable for 90 C Replace cover plate Connect power with flexible conduit or appropriate cord to allow heater to be swiveled Junction Box on top of the heater has a gasket side access cover The Junction Box inlet hol...

Page 4: ...inimum clearance is maintained around the heater on all four sides and 36 91 4cm directly in front A minimum of 6 15 24cm of clearance provided by mounting brackets is required behind the plane of the face Heater can be hung using chains or custom brackets Heater must be level but can be rotated around its horizontal axis Heater must be installed with the quartz tube horizontally level For maximum...

Page 5: ...eplacement elements for your Infratech heatingsystem pleasecontact usviaphoneorvisitourwebsite Consultthe labelonbackof heaterforproperwatts voltage andreplacementelementpart number REPLACEMENT ELEMENTS OTHER VOLTAGES ALSO AVAILABLE PART NUMBER ELEMENT NUMBER LENGTH WATTS VOLTS FITS 10 1020 E 7512 16 1 2 0 4m 750 120 C 7512 10 1050 E 1412 30 0 8m 1500 120 C 1512 10 1055 E 1424 30 0 8m 1500 240 C 1...

Page 6: ...egulator This low cost controller which is actually an infinite switch gently pulses the heat on and off at regular intervals when not on full power Dual Element Heaters can be wired with our Duplex Stack Switch which enables the ability to turn on and off each element independently providing for half power full power capabilities For ideal comfort heat the best solution is to heat from two sides ...

Page 7: ...TING Unless heaters are installed over 12 3 7m high it is generally recommended that all radiant heaters be mounted on an angle to assure that radiant warmth is distributed from the sides rather than straight down on the heads and shoulders of the people being warmed LOCATION SUGGESTIONS Angle fixture 30º to 60º from horizontal face down Best angle is approximately 45º Install fixture to heat the ...

Page 8: ... is not responsible for consequential or incidental damages Under no circumstances shall INFRATECH or any of its representatives be held liable for injury to any person or damage to any property however arising Important Please retain original proof of purchase to establish warranty period Any implied warranties of merchantability and fitness applicable to the equipment are limited in duration to ...