Chapter 2 - Commissioning
9
XtrapulsCD1-pm - User manual
Chapter 2 - Commissioning
WARNING
During the machine adjustments, some drive connection or parameterization errors may involve
dangerous axis movements. It is the user's responsibility to take all necessary steps in order to
reduce the risk due to uncontrolled axis movements during the operator's presence in the
concerned area.
1
– COMMISSIONING OVERVIEW
The various stages of a first positioner commissioning are described below:
Both operation stages are:
The positioner parameters are accessible via:
- the serial link and the PC parameterization software,
- or by the PKW of the PROFIBUS DP.
CAUTION !
Do not make the drive parameterization by means of both PC software and Profibus at the same time.
SERVO CONTROL ADJUSTMENT
(chapter 2 section 8)
MOTOR ADJUSTMENT
(chapter 2 section 7)
CONFIGURATION
(chapter 4 section 2)
PROFIBUS COMMUNICATION
(PROFIBUS communication profile
manual)
- Current regulator adjustment.
- Definition of the current limitations and of the I
2
t protection.
- Adjustment of the motor control parameters.
- Speed limitation definition.
- Rotation direction.
- Adjustment of the servo control parameters according to the
load.
- Definition of the resolution.
- Limit switches.
- Following error.
PROFIBUS operation mode :
- Communication start between PLC and positioner.
PROGRAMMATION
(chapter 4 section 3)
PROFIBUS OPERATION
(PROFIBUS communication profile
manual)
- Sequences programmation.
PROFIBUS operation mode :
- "Operational" phase: sequences execution by Profibus.
!