![Infranor XtrapulsCD1-pm User Manual Download Page 53](http://html.mh-extra.com/html/infranor/xtrapulscd1-pm/xtrapulscd1-pm_user-manual_2058369053.webp)
Appendix
53
XtrapulsCD1-pm - User manual
3.2
– USE OF THE TERMINAL
3.2.1
– MAIN MENU
In the main menu, keys 1, 2, 3 or 4 allow:
1. To display the motor position. The operator can then move the motor (Jog+ or Jog-) by means of the arrow
keys.
2. To modify a given sequence:
* Position modification of a given sequence: the operator enters the sequence number and the new position.
* Speed modification of a given sequence: the operator enters the sequence number and the newly programmed
speed.
3. To start a sequence: the operator enters the number of the sequence to be executed.
4. To move until a position: the operator enters the position and moves the motor until this position.
3.2.2
– POSITION DISPLAY
The arrow keys allow moving the motor (Jog+ or Jog-), when the ENABLE
signal is activated.
The key allows the operator getting back to the main menu.
In this window, the operator can stop the motor (if it is rotary one) by pressing the key.
The operator must press the key for confirming the motor stopping or any other key for cancelling.
1
Display position
2
Modify sequence
3
Run sequence
4
Move_
CD1-pm
103.
øøø
mm
RETURN
0
STOP?_
RETURN