31
6-9 Trigger Command Generating and Cancelling
1. The FV5X can be controlled by the command from computer or PLC to read the code.
The default trigger command (hex) is "544F4E", and the trigger cancellation command
(hex) is "544F4646";
2. Set the trigger command, for example, set "LON" as the trigger command, select
"Transformation Assistant", and input "LON" to convert "LON" to the corresponding
hexadecimal;
3. Copy the Hex content converted by "LON", paste it into "Enable trigger command", click
"OK", you can view it in the setting list, click "Download Configuration" to complete the
setting;
4. The custom trigger cancellation command is as the same set process as above.