Copyright ©2018, Infoblox, Inc.All right reserved.
UID Button
The unit identification button. In a rack environment, the UID feature enables easier location of a server when moving
between the front and rear of the rack. You can also identify the appliance through the Grid Manager and CLI command.
Grounding Post
For DC installations, you securely connect a grounding wire to the chassis and to earth ground, which typically is the
equipment rack on which you install the appliance. The mounting nut is placed on the grounding post for convenience.
Remove the mounting nut, place the grounding wire connector onto the grounding post and replace the mounting
nut.Ensure that it is snug.
Power Supplies
Each of the two redundant power supplies has a three-prong power outlet for connecting the appliance to a standard AC
(Alternating Current) power source.
System, Environmental, and Power Specifications
System specifications describe the physical characteristics of the Infoblox 4005 Series appliances. Environmental specifications describe Infoblox
4005 Series temperature and moisture limits. Power specifications describe the electrical range within which the appliance circuitry can operate.
This chapter reports power usage and heat generation characteristics against the hardware configuration for the Infoblox 4005 Series appliances.
Optional hardware configurations that affect electrical power budgets include the following:
Use of a single power-supply or 1+1 redundant PSU (power supply unit) configuration (see
).
Appliance Rear Panel
1 GbE SFP network interface card (see
).
SFP/SFP+ Interface Support
10 GbE SFP+ network interface card (see
).
SFP/SFP+ Interface Support
You may choose to order a field-replaceable power supply to upgrade your appliance to a 1+1 redundant configuration. Doing so changes the
power usage and heat generation characteristics for your appliance. The same is true if you change out your AC power supply configuration for
DC power supplies. Consult the specifications for your appliance for both AC and DC information.
System Specifications
Form Factor: 2-U rack-mountable appliance
Dimensions: 88mm H x 441mm W x 534mm D
Weight: Approximately 29 lbs (13.15 kg)
Ethernet Ports: MGMT, HA, LAN1, LAN2 – auto-sensing 10Base-T/100Base-T/1000Base-T
Serial Port: DB-9 (9600/8n1, Xon/Xoff)
USB Ports: USB 3.0
Safety: FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, EAC
Environmental Specifications
Operating Temperature: 41°F – 95°F (5 – 35°C)
Storage Temperature: –40°F – 122°F (–40°C – 50°C)
Operating Relative Humidity: 5% to 95% (non-condensing)
Airflow CFM (Cubic Feet/Minute): 203 CFM
Airflow Direction: Front-to-Back
Environmental Certification: WEEE and RoHS
Electrical Power Specifications
AC Power Supply: 110 to 240VAC 600W (Maximum)
Input Frequency: 50 to 60 Hz
Input Current: 7.5A @ 100V AC, 3.5A @ 240V AC
Inrush Current: <25A max at 240V
Heat Output (BTU/hour): 2355 Max
Power Consumption
IB-40x5-BASE-AC: 283W
IB-40x5-1GE-AC: 291W
IB-40x5-10GE-AC: 308W
IB-40x5-BASE-DC: 251W
IB-40x5-1GE-DC:311W