8.  QUICK START GUIDE

Step 1: Preparing to Use the BOLT TD50L Series

1.  Compare the box contents to the accessories list and examine 

each for any shipping damage. See 

Accessories

 on page 4. 

2.  Check the lens to ensure there are no smudges or dirt present. 

Clean with the included lens cloth, if necessary. 

3.  Install the eyeguard 

(1)

.

4.  Charge the built-in battery pack before using the BOLT TD50L 

for the first time. See 

Charging the Built-in Battery Pack

 on 

page 10.

5.  Mount the BOLT TD50L to the weapon using the included 30mm 

rings. See 

Mounting the BOLT TD50L

 on page 15.

Step 2: Turn On the BOLT TD50L and Adjust the 

Focus

1.  Open the objective lens cap 

(15)

. If the sunlight is too bright, you 

may leave the lens cap closed to prevent the image from being 

overexposed.

2.  Long press the 

Power

 

 

Button 

for 2 seconds to power on the 

BOLT TD50L. The InfiRay logo will appear.

3.  Rotate the diopter adjustment ring 

(2)

 of the eyepiece until the 

interface icons are clearly visible.

4.  Rotate the objective lens focus ring 

(14)

 to focus on the object 

being observed.

WARNING: 

 Do not point the objective lens toward intense 

energy sources, such as the sun. This may render the electronic 

components inoperative. The warranty does not cover damage 

caused by improper operation.

Step 3: Activate and Customize the Reticle

From the home screen:

1.  Press and hold the 

Brightness 

 and 

Palette   Buttons 

at the 

same time for 15 seconds to activate the reticle.

2.  Short press the 

Control Turret

 to enter the quick menu (see 

Using the Quick Menu

 on page 21): 

a.  Select the reticle color, white, black, red, or green. The 

default is white.

b.  Select the reticle type, from 1–6. The default type is 1.

Step 4: Adjust the Image Settings

From the home screen:

1.  Short press the 

Palette   Button

 to set the imaging mode, day, 

moon, and star. Day is the default.

2.  Short press the 

Brightness 

 

Button

 to adjust the screen 

brightness, from level 1–5. The selected screen brightness

 

appears in the status bar. The default is 3.

3.  Rotate the 

Control Turret

 to zoom in and out on the observed 

object. See 

Digital Zoom

 on page 29

4.  Long press the 

Palette   Button 

to turn on the PIP window, if 

desired. See 

Picture in Picture (PIP)

 on page 29.

Step 5: Adjust Rifle Scope Settings

1.  From the home screen, long press the 

Control Turret

 to enter 

the main menu to: 

a.  Set the date and time. See 

Settings Menu > Date

 on 

page 38 and 

Settings Menu > Time

 on page 39.

b.  Set the units of measurement, meters or yards. The default is 

yards. See 

Settings Menu > Units of Measure

 on page 40.

Step 6: Zero the BOLT TD50L

1.  From the home screen, long press the 

Control Turret

 to enter 

the main menu to: 

a.  Select the zeroing profile, A, B, or C. See 

Main Menu > 

Zeroing Profile

 on page 32.

b.  Select, or customize, a preset zero distance that matches 

the target distance. See 

Zeroing Menu

 on page 33.

c.  Zero the reticle. See 

Zeroing Menu > Reticle Zeroing

 on 

page 34.

Summary of Contents for BOLT DIGITAL Series

Page 1: ...I N F I R A Y O U T D O O R BOLT DIGITAL SERIES Bolt Action Optimized Digital Night Vision Scope User s Manual Outdoor...

Page 2: ...the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the d...

Page 3: ...i Fi module for external connectivity to App Picture in Picture PIP Extended eye relief User friendly interface 3 TECH SPECS BOLT TD50L SERIES TD50L SENSOR Resolution 1440 1080 Pixel Size 4 m Frame Ra...

Page 4: ...AC18 BOLT Standard Scope Mount Rings IRAY AC37 BOLT 18650 Battery Extender IRAY AC70 BOLT Digital Series Infrared Illuminator IRAY AC71 Standard Rubber Eyeguard for BOLT IRAY AC74 Objective Lens Cap...

Page 5: ...ort Press Long Press Home screen Adjust the screen brightness Enter exit the stadiametric rangefinder Photo Button Current Screen Menu Short Press Long Press Home screen Take a photo Start stop record...

Page 6: ...s and hold the Brightness and Palette Buttons at the same time for 15 seconds to activate the reticle 2 Short press the Control Turret to enter the quick menu see Using the Quick Menu on page 21 a Sel...

Page 7: ...battery b See Battery Status Icons on page 12 for additional battery information WARNING Never charge the battery pack with a USB adapter that is greater than 5V 2A NOTES You may charge and operate B...

Page 8: ...included are compatible with the BOLT TD50L Using with the Optional Auxiliary Battery When both the built in battery pack and the auxiliary battery are fully charged the BOLT TD50L will select the aux...

Page 9: ...y turning it counterclockwise 2 Connect the smaller USB C end of the data cable to the USB C port 9 3 Connect the standard USB end of the data cable to the external power supply The BOLT TD50L will au...

Page 10: ...ses concentrated infrared light which while not visible to the human eye can cause permanent physical damage 17 OPERATING INSTRUCTIONS Control Features The BOLT TD50L is operated via four control butt...

Page 11: ...icle appear sharp and in focus No additional diopter adjustments are required unless the user wishes to make changes NOTES After this initial adjustment there is no need to rotate the eyepiece adjustm...

Page 12: ...on the operating status of the BOLT TD50L Series 1 2 3 4 5 6 7 8 9 1 Imaging Mode Shows the set imaging mode day moon star Day is the default 2 Zeroing Profile Distance Shows the selected zero profile...

Page 13: ...he desired zero distance 2 Confirm that the rifle is empty safe and pointed in a safe direction with no ammunition near the weapon 3 Adjust the image and device settings following the steps in the Qui...

Page 14: ...Recorded photos are saved to the internal memory card in jpg format videos are saved in mp4 format a Photos are saved in IMG_HHMMSS_XXX jpg format b Videos are saved in VID_HHMMSS_XXX mp4 format c HH...

Page 15: ...3 Enter the Wi Fi password The default password is 12345678 4 Press the Join button When Wi Fi is successfully connected the user may manipulate the BOLT TD50L via the InfiRay Outdoor App See Using th...

Page 16: ...app are saved to the mobile device instead of the internal storage of the BOLT TD50L Once connected you can access files saved to the mobile device In the App press the ViewFinder icon at the bottom...

Page 17: ...xpand the space between the lines b Rotate counterclockwise to shrink the space between the lines 2 As you adjust the space between the horizontal lines the rangefinder values on the right side of the...

Page 18: ...C with distance selected See the Zero Distance Submenu and Reticle Zeroing on the next page for instructions on customizing the nine zero distances 1 Long press the Control Turret to enter the main m...

Page 19: ...sition 5 White Dot Indicates center of initial reticle position NOTE The red X indicates the point of impact It is shown in the figure for illustration purposes and is not an interface element To zero...

Page 20: ...e two triangle icons will indicate the selected digit 5 Long press the Control Turret to save the custom zero distance and return to the Zero Distance submenu 6 The new zero distance appears in the st...

Page 21: ...ss the Control Turret to switch between digits The two triangle icons indicate the selected digit 5 Long press the Control Turret to save the date and return to the home screen SETTINGS MENU TIME Set...

Page 22: ...ol Turret to select the status auto hiding menu item 2 Short press the Control Turret to enter the auto hiding submenu 3 Rotate the Control Turret to move through the options on and off Auto hiding is...

Page 23: ...ing your published warranty period iRayUSA will repair or replace at its discretion any optic that becomes defective during normal use Additionally if we cannot fix your optic in less than one week we...

Page 24: ...microfiber lens cloth There is condensation on the interior or exterior optical surfaces of the lens Wipe the outside optical surfaces with the included microfiber lens cloth Allow the BOLT TD50L to...

Page 25: ...ubject to change without notice For the most up to date specs go to irayusa com Not responsible for typographical errors Ver 1 1080122 800 Railhead Road 316 Fort Worth TX 76106 800 769 7125 682 499 00...