background image

28

29

3.  Press the 

Settings

   

icon

4.  In the password field, 

enter the new Wi-Fi 

password and tap the 

Submit button

. The 

password must be 8–16 

numbers/letters. 

5.  If you also wish to reset 

the SSID, enter a new 

Wi-Fi name in the SSID 

field.

6.  Turn off the BOLT TD50L 

to put the new password 

(and SSID, if changed) 

into effect. 

7.  Wait at least 30 seconds before restarting the device.
8.  On the mobile device, go to 

Settings

 > 

Wi-Fi

, enter the new 

password, and press the 

Join button

.

NOTE: When a factory reset is performed, the Wi-Fi password and 

SSID are reset to the defaults, 12345678 and BOLT_XXXXXX. See 

Settings Menu > Factory Reset

 on page 41.

22. USING THE INFIRAY 

OUTDOOR APP 

The BOLT TD50L Series 

rifle scope supports 

operation via the InfiRay 

Outdoor App when 

the BOLT TD50L is 

connected via Wi-Fi to a 

smartphone or tablet. See 

Main Menu > Wi-Fi

 on 

page 31.

You can download and 

install the InfiRay Outdoor 

App for free via any app store, or by scanning one of the QR codes 

at right to download the InfiRay Outdoor App from the App Store or 

Google Play.

When Wi-Fi is connected, users can manipulate the BOLT TD50L via 

the InfiRay Outdoor App, including: 

•  Take real-time photos and videos, with or without audio. 
•  Photos and videos taken via the app are saved to the mobile 

device, instead of the internal storage of the BOLT TD50L. Once 

connected, you can access files saved to the mobile device:

•  In the App, press the 

ViewFinder icon

   at the bottom of 

the screen.

•  Press the photo and video icons at the bottom of the screen 

to view photos and videos, as well as share, delete, and 

download files.

•  Change the Wi-Fi password and SSID. See 

Setting a New Wi-Fi 

Password and SSID

 on page 27.

•  Synchronize date and time from the mobile device with the BOLT 

TD50L:

•  In the App, press the 

ViewFinder icon

   at the bottom of 

the screen.

•  Press the 

Settings icon

   at top-right. 

•  Click the 

Synchronize Time button

.

•  Upgrade the firmware. See 

Firmware Upgrade

 on page 27.

23. DIGITAL ZOOM 

The BOLT TD50L Series 

TD50L uses continuous 

zoom and can quickly 

increase the base 

magnification from 

4× to 16× by enlarging the 

image from 1 to 4 times 

digitally. 

To use digital zoom: 

1.  From the home 

screen, rotate the 

control turret to zoom in and out on the observed object. 

a.  Rotate clockwise to zoom in, counterclockwise to zoom out. 
b.  Each rotation click zooms in / out in increments of 0.4×. 

2.  The real-time amplification number, 4–16×, appears in status bar.

24. PICTURE IN PICTURE (PIP)

The PIP (Picture in 

Picture) function opens 

a small floating window 

with a magnified image-

view at the top of the 

screen. PIP allows for 

improved aiming while 

still being able to see the 

wide field of view in the 

main body of the screen. 

Summary of Contents for BOLT DIGITAL Series

Page 1: ...I N F I R A Y O U T D O O R BOLT DIGITAL SERIES Bolt Action Optimized Digital Night Vision Scope User s Manual Outdoor...

Page 2: ...the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the d...

Page 3: ...i Fi module for external connectivity to App Picture in Picture PIP Extended eye relief User friendly interface 3 TECH SPECS BOLT TD50L SERIES TD50L SENSOR Resolution 1440 1080 Pixel Size 4 m Frame Ra...

Page 4: ...AC18 BOLT Standard Scope Mount Rings IRAY AC37 BOLT 18650 Battery Extender IRAY AC70 BOLT Digital Series Infrared Illuminator IRAY AC71 Standard Rubber Eyeguard for BOLT IRAY AC74 Objective Lens Cap...

Page 5: ...ort Press Long Press Home screen Adjust the screen brightness Enter exit the stadiametric rangefinder Photo Button Current Screen Menu Short Press Long Press Home screen Take a photo Start stop record...

Page 6: ...s and hold the Brightness and Palette Buttons at the same time for 15 seconds to activate the reticle 2 Short press the Control Turret to enter the quick menu see Using the Quick Menu on page 21 a Sel...

Page 7: ...battery b See Battery Status Icons on page 12 for additional battery information WARNING Never charge the battery pack with a USB adapter that is greater than 5V 2A NOTES You may charge and operate B...

Page 8: ...included are compatible with the BOLT TD50L Using with the Optional Auxiliary Battery When both the built in battery pack and the auxiliary battery are fully charged the BOLT TD50L will select the aux...

Page 9: ...y turning it counterclockwise 2 Connect the smaller USB C end of the data cable to the USB C port 9 3 Connect the standard USB end of the data cable to the external power supply The BOLT TD50L will au...

Page 10: ...ses concentrated infrared light which while not visible to the human eye can cause permanent physical damage 17 OPERATING INSTRUCTIONS Control Features The BOLT TD50L is operated via four control butt...

Page 11: ...icle appear sharp and in focus No additional diopter adjustments are required unless the user wishes to make changes NOTES After this initial adjustment there is no need to rotate the eyepiece adjustm...

Page 12: ...on the operating status of the BOLT TD50L Series 1 2 3 4 5 6 7 8 9 1 Imaging Mode Shows the set imaging mode day moon star Day is the default 2 Zeroing Profile Distance Shows the selected zero profile...

Page 13: ...he desired zero distance 2 Confirm that the rifle is empty safe and pointed in a safe direction with no ammunition near the weapon 3 Adjust the image and device settings following the steps in the Qui...

Page 14: ...Recorded photos are saved to the internal memory card in jpg format videos are saved in mp4 format a Photos are saved in IMG_HHMMSS_XXX jpg format b Videos are saved in VID_HHMMSS_XXX mp4 format c HH...

Page 15: ...3 Enter the Wi Fi password The default password is 12345678 4 Press the Join button When Wi Fi is successfully connected the user may manipulate the BOLT TD50L via the InfiRay Outdoor App See Using th...

Page 16: ...app are saved to the mobile device instead of the internal storage of the BOLT TD50L Once connected you can access files saved to the mobile device In the App press the ViewFinder icon at the bottom...

Page 17: ...xpand the space between the lines b Rotate counterclockwise to shrink the space between the lines 2 As you adjust the space between the horizontal lines the rangefinder values on the right side of the...

Page 18: ...C with distance selected See the Zero Distance Submenu and Reticle Zeroing on the next page for instructions on customizing the nine zero distances 1 Long press the Control Turret to enter the main m...

Page 19: ...sition 5 White Dot Indicates center of initial reticle position NOTE The red X indicates the point of impact It is shown in the figure for illustration purposes and is not an interface element To zero...

Page 20: ...e two triangle icons will indicate the selected digit 5 Long press the Control Turret to save the custom zero distance and return to the Zero Distance submenu 6 The new zero distance appears in the st...

Page 21: ...ss the Control Turret to switch between digits The two triangle icons indicate the selected digit 5 Long press the Control Turret to save the date and return to the home screen SETTINGS MENU TIME Set...

Page 22: ...ol Turret to select the status auto hiding menu item 2 Short press the Control Turret to enter the auto hiding submenu 3 Rotate the Control Turret to move through the options on and off Auto hiding is...

Page 23: ...ing your published warranty period iRayUSA will repair or replace at its discretion any optic that becomes defective during normal use Additionally if we cannot fix your optic in less than one week we...

Page 24: ...microfiber lens cloth There is condensation on the interior or exterior optical surfaces of the lens Wipe the outside optical surfaces with the included microfiber lens cloth Allow the BOLT TD50L to...

Page 25: ...ubject to change without notice For the most up to date specs go to irayusa com Not responsible for typographical errors Ver 1 1080122 800 Railhead Road 316 Fort Worth TX 76106 800 769 7125 682 499 00...