14
Appendix Questions & Solutions
The following table describes the symptoms causes, and solutions for the problems.
Symptoms
Possible Causes
Solutions
Wrong power connection
Reconnect power cable
Power supply failure
Repair or replace power supply
The IP dome does not perform
initiation sequence after
powering on
Power PCB fuse damage
Replace the fuse
New camera ID has not been activated
Recycle the power
Camera ID was set wrong
Reset camera ID
The IP dome can’t be controlled
After successful initiation.
Protocol or Baud rate of PTZ Settings are
incorrectly chosen
Proper set the Protocol and Baud rate
Don’t correctly install the inserter to view
the images
Refer to the inserter Installation to
reinstall it
Don’t correctly set the security level of
the browser
Refer to the browser setting to reset it
Dome’s IP address conflict with other
user’s IP address
Set the unique IP address
No video signal displayed
Don’t correctly initialize the coding
module
Restart or after power-off
Unclear down cover
Clean the down cover
Vague image
Manual focus has been set
Set focus mode to "auto"
or