8.4 4. No data is being transferred
The wireless link is established but no data is being transffered.
Step 1: Local and remote units settings check
Connect to the unit web interface and check the matrix connectivity in the "Switch" section, ge0
port must be connected with the radio port.
Check the operation status of the ge0 port. Enable the port if it was disabled. In case of using
VLANs, proceed to the "Switch" section and make sure that the VLAN configuration is correct,
the specific traffic VLAN ID is allowed to pass through the port.
If the port status is "Up" but no packets are received, check the configuration of the equipment
which is directly connected.