![Infineon IM393 Series Application Note Download Page 20](http://html.mh-extra.com/html/infineon/im393-series/im393-series_application-note_2055154020.webp)
Application Note
20 of 53
V 1.0
2019-04-01
IM393 Application note
IM393 IPM Technical Description
Interface circuit and layout guide
Notes:
1.
Input circuit
- RC filter can be used to reduce input signal noise. (100
Ω
, 1 nF)
- The capacitors should be located close to CIPOS
™
Tiny (to COM terminal especially).
2.
Itrip circuit
- To prevent a malfunctioning of the protection function, an RC filter is recommended.
- The capacitor must be located close to Itrip and COM terminals.
3.
VTH circuit
- This terminal should be pulled up to the bias voltage of 5 V/3.3 V by a proper resistor to define suitable
voltage for temperature monitoring.
- It is recommended that the RC filter be placed close to the controller.
4.
VB-VS circuit
- Capacitors for high-side floating supply voltage should be placed close to VB and VS terminals.
- Additional high-frequency capacitors, typically 0.1 μF, are strongly recommended.
- Overlap of pattern-to-motor and pattern-to-bootstrap capacitors should be minimized. (SIP only)
5.
Snubber capacitor
- The wiring between CIPOS
™
Tiny, snubber capacitor and shunt resistors should be as short as possible.
6.
Shunt resistor
- SMD-type shunt resistors are strongly recommended to minimize internal stray inductance.
7.
Ground pattern
- Pattern overlap of power ground and signal ground should be minimized. The patterns should be
connected at the common end of the shunt resistors only, for the same potential.
8.
COM pattern
- In the case of a DIP package, pins 24, 25 and 26 must be left unconnected, as COM is connected to pin 29, 28
and 27 by the shunt resistor.
- It is highly advisable to connect both pins 14 and 15 together.
9.
RFE circuit
- To set up R and C parameters for fault-clear time, please refer to Figure 5.
- For normal operation, RFE (pin 17) should always be pulled up to 5 V or 3.3 V via the pull resistor.
- This R is also mandatory for fault reporting function, as it is an open-drain structure.
10.
P pattern
- In the case of a DIP package, pin 1 can be left unconnected, as positive bus voltage is connected by pins 35
and 33 that are internally connected to pin 1.
4.3
Recommended circuit current of power supply
Control and gate driver power for the IM393-XX is normally provided by a single 15 V supply that is connected to
the module VDD Pin. The circuit current of VDD control supply of IM393-L6E is shown in below Table 6.
Table 6
The circuit current of control power supply of IM393-L6E (Unit:[mA])
Item
Static (Typ.)
Dynamic (Typ.)
Total (Typ.)
V
DD
= 15 V
F
SW
= 5 kHz
4.02
0.26
4.28
F
SW
= 15 kHz
4.02
0.78
4.83
V
DD
= 20 V
F
SW
= 20 kHz
8.03
4.08
12.11
And the circuit current of the 5 V logic power supply (VTH, RFE and input terminal) is about 20 mA.
Finally, the recommended minimum circuit currents of power supply considering margins are shown in Table 7.