To avoid switching due to mechanical vibrations of the rotor, an artificial hysteresis is recommended (
).
Electrical angle switching
hysteresis
5)
α
HShystel
0.70
°
1 pole pair;
IFAB_HYST=11
1.41
°
2 pole pairs;
IFAB_HYST=11
2.11
°
3 pole pairs;
IFAB_HYST=11
2.81
°
4 pole pairs;
IFAB_HYST=11
3.52
°
5 pole pairs;
IFAB_HYST=11
4.22
°
6 pole pairs;
IFAB_HYST=11
4.92
°
7 pole pairs;
IFAB_HYST=11
5.62
°
8 pole pairs;
IFAB_HYST=11
6.33
°
9 pole pairs;
IFAB_HYST=11
7.03
°
10 pole pairs;
IFAB_HYST=11
7.73
°
11 pole pairs;
IFAB_HYST=11
8.44
°
12 pole pairs;
IFAB_HYST=11
9.14
°
13 pole pairs;
IFAB_HYST=11
9.84
°
14 pole pairs;
IFAB_HYST=11
10.55
°
15 pole pairs;
IFAB_HYST=11
11.25
°
16 pole pairs;
IFAB_HYST=11
Fall time
t
HSfall
0.02
1
μ
s
R
L
= 2.2k
Ω
; C
L
< 50pF
Rise time
t
HSrise
0.4
1
μ
s
R
L
= 2.2k
Ω
; C
L
< 50pF
1) Depends on internal oscillator frequency variation (see Data Sheet)
2) Not subject to production test - verified by design/characterization
3) GMR hysteresis not considered
4) Minimum hysteresis without switching
5) The hysteresis has to be considered only at change of rotation direction
Table 5-12 Hall Switch Mode
(cont’d)
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.