Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com
12
SPECIFICATIONS
ECOPOD-N Unit Specifications
Treatment
Plant
Treatment
Capacity (GPD)
Minimum Primary
Tank Total
Volume (Gal)
Reactor Tank
Volume
(Gal)
Reactor Tank
Dilution Volume
(Gal)
Media
Size
Air
Requirements
E50N
500
500
710
590
2'x2'x4'
12 CFM
E60N
600
600
916
736
2'x2'x6'
14.4 CFM
E75N
750
750
1090
910
2'x2'x6'
18 CFM
E100N
1000
1000
1405
1165
2'x2'x8'
24 CFM
E150N
1500
1500
2100
1740
2'x2'x6'
36 CFM
MATERIALS OF CONSTRUCTION
Suffix FF
Reactor Tank
Fiberglass
Cover
Fiberglass
Media Container
Polyethylene
Suffix CA
Reactor Tank
Concrete
Cover
Concrete
Media Container
Polyethylene
Suffix IM
Reactor Tank
Polypropylene
Cover
Polypropylene
Media Container
Polyethylene
These are standard production units. Other configurations are available upon request.
ECOPOD-N Electrical Requirements
Model
Compressor
Motor Full Load Amps
Measured Operating Watts
Electrical Requirements
E50N
Delta Model 06
3.5
185
115 volt – single phase
E60N
Delta Model 06
4.7
280
115 volt – single phase
E75N
Delta Model 06
4.7
280
115 volt – single phase
E100N
Delta Model K03
7.1
475
115 volt – single phase
E150N
Delta Model K03
7.1
475
115 volt – single phase
ECOPOD-N Reactor Tank Dimensions
Treatment Plant
A
B
C
D
E50N
47”
44”
54.7”
127”
E60N
47”
44”
54.7”
127”
E75N
47”
44”
54.7”
127”
E100N
47”
44”
55”
176”
E150N
47”
44”
55”
176”