02VJ-004 rev.2
RF Pilot
Wireless remote controller with display
EN
Perenmarkt 10B, 1681PG ZWAAGDIJK-OOST ind.terrein: WFO/ABC THE NETHERLANDS
Tel: +31(0)228-567729, Fax: +31(0)228-567797, Email: info @ wardenaar.com, Internet: www.wardenaar.com
Rabobank 32 69 98 268, KvK te Alkmaar 37079598, BTW NL 8070.48.768.B01
Battery insertion Device description Display description - basic display
+
-
+
-
Display
Direction
button
Control
button T1
Control
button T2
Time
Date
Current temperature
display
Enter the menu
Quick Control
options
Battery
cover
Low battery
indicator
Remove the battery cover and insert two R03/
AAA batteries as indicated.
Battery
cover
Device
mo 01.01.10 12:54
Favourite 1
Favourite 2
Favourite 3
Favourite 4
Favourite 5
Favourite 6
Favourite 7
Temp.: 23C MENU
The memory has an independent power supply. Any custom adjustment (except for time and date) will remain.
After inserting the batteries, the RF Pilot name and the fi rmware number will appear on the initial screen.
Radio frequency signal penetration through various construction materials
Basic Steps for Successful Programming of RF Pilot
Step 1 - Location of RF units
Keep in mind that the radio signal range for RF installations depends on the building structure, materials
used and the manner of unit location in the area.
Step 2 - Complete the Installation Form
- name of the device you want to control
- names of units (e.g.: RFSA-61B, ...)
- addresses of units (e.g.: 577515, ...)
(The Installation Form is included at the end of the Manual).
Name
Address
E.g.: RFSA-61B
E.g.: 577515
Step 3 - Add actuator
Add
actuators and their addresses into the Controller memory.
Step 4 - Allocation of actuators to rooms
Allocation
of actuators to rooms.
Step 5 - Optional setting
Rename
actuator according to your requirements.
Test
of the range and RF signal
quality.
Rename
Room. Create
Scene
. Saving most frequently used Actuators / Rooms
/ Scenes in the Initial Screen Favourite as shortcuts.
☺
☺
☺
☺
☺
RF
RP
-2
0
60 - 90 %
80 - 95 %
20 - 60 %
0 - 10 %
80- 90 %
brick walls
wooden structures
with plaster boards
reinforced
concrete
metal partitions
common
glass
Controller Activation Settings Menu / Settings - Language
T1
T2
Fig. 3
mo 01.01.10 12:54
Rooms
Scenes
Favourite
EXIT SELECT
T1
T2
Fig. 2
mo 01.01.10 12:54
Favourite 1
Favourite 2
Favourite 3
Favourite 4
Favourite 5
Favourite 6
Favourite 7
Temp.: 23C MENU
Fig. 1
As standard, the display is in the sleep mode - no information is displayed
(Fig. 1).
Press any button briefl y to display the
Initial Screen
(Fig. 2).
Press T1 to enter the
Basic Menu
(Fig. 3).
Note: When using the controller, 10 seconds after pressing any button, the RF Pilot switches
to the sleep mode. In the Settings Menu, it switches to the sleep mode 40 seconds after
pressing any button.
Settings Menu
To enter the Settings Menu (Fig. 5), press the left side of the direction button together with the T1
button (Fig. 4) in the Basic Menu.
T1
mo 01.01.10 12:54
Rooms
Scenes
Favourite
EXIT SELECT
Fig. 4
T1
T2
Language
Date and time
Actuators
Rooms
Scenes
Favourite
Device reset
EXIT SELECT
Fig. 5
T2
T1
Cestina
Slovencina
English
Deutsch
Magyar
Pyccии яз.
Romana
Polski
EXIT SELECT
Fig. 7
T2
T1
Language
Date and time
Actuators
Rooms
Scenes
Favourite
Device reset
EXIT SELECT
Fig. 6
Language
Used for language setting. Press T1 (Fig. 6) to enter the Language Menu. Choose the requested
language using the direction button (Fig. 7). Confirm using the T1 button.
2/8