86014010_04_OPERATING_MANUAL_VC400_LCD_GB.DOC 25.11.2016 KS
page 25
14.
R
elease the vacuum with the valve ‘flask’.
If the crucible was put under over- or under-pressure, also release it with the
valve
‘crucible’ to ‘normal’ position.
15.
Lower the vacuum chamber with the valve ‘chamber lift’ and swing out the
chamber.
Now the flask can be removed.
-
Before or just after opening the sealing rod, the pressure at the top of the flask
can be changed with the valve ‘crucible’ to normal-pressure, under-pressure or
over-pressure.
A new casting cycle can start, beginning with step 3.
If casting process is finished:
1. Press "Generator stop".
2. Vacuum pump should run at least 5 minutes after last casting to remove humidity.