4.1.3 Pre-set casting programs
VC400 /
VC500
Material
Bronze
Yellow
gold 14k
(with
zinc)
Yellow
gold 18k
Aluminium
Brass
Silver
935
Test
Crucible
Graphite
Graphite
Graphite
Graphite
Graphite
Graphite
Graphite
Program No.
10
11
12
13
14
15
18
Temperature °C
1150
1060
1080
740
1080
1000
0010
Heating
power
%
0100
0100
0100
0100
0100
0100
100
Turbo
pressure
start
s
00.8
00.8
00.8
00.8
00.8
00.8
00.8
Turbo
pressure
maximum
bar
1.00
1.00
1.00
1.00
1.00
1.00
0.50
Label
Bronze
YG 585
750/YG
Aluminum Brass
935/Ag
InduTest
4.1.4 VC400 modify system parameter
If you start from the start page and you press“ Program setup“ for 5 seconds you get
access to the system parameter.
On the top level shown:
000:00002
== selected parameter == 000
value of parameter 00002: equals two == type N thermocouple
If
you press “Λ” you get access to the parameter 001 and higher.
By pressing “+” you change the value of parameter 000 to 3
Summary of Contents for VC 400 LCD
Page 27: ...86014010_04_OPERATING_MANUAL_VC400_LCD_GB DOC 25 11 2016 KS page 27 4 4 Configuration of flask...
Page 37: ...86014010_04_OPERATING_MANUAL_VC400_LCD_GB DOC 25 11 2016 KS page 37...
Page 38: ...86014010_04_OPERATING_MANUAL_VC400_LCD_GB DOC 25 11 2016 KS page 38 7 Connection diagrams...
Page 39: ...86014010_04_OPERATING_MANUAL_VC400_LCD_GB DOC 25 11 2016 KS page 39...
Page 40: ...86014010_04_OPERATING_MANUAL_VC400_LCD_GB DOC 25 11 2016 KS page 40...