Operation
s [email protected] | roma noff.com
7-19
7.13
Diagram casting flasks without flange
Figure 25: Flasks without flange
vacuum area
force of the air
pressure
force of the
overpressure
Possible reasons of losing vacuum:
1.)
O-Ring of vacuum chamber is not OK.
2.)
Flask top surface is not flat enough.
3.)
Silicon ring is missing or faulty.
4.)
Flask cylinder is not in ‘up’ position.
5.)
By using overpressure on the crucible
area you need 8 bars air pressure.
With 6 bars pressure the flask will
move down and the vacuum will be
lost.
6.)
Flask has cracks.
7.)
‘Flask’ isn’t selected in Program Set-
up.
7.14
Diagram casting flasks with flange
Figure 26: Flasks with flange
vacuum
area
force of the
overpressure
Possible reasons of losing vacuum.
1.)
Flask flange is not flat enough.
2.)
Silicon ring is missing or faulty.
3.)
Flask has cracks.
4.)
‘Flask Fl’ is not selected in program
setup.
7.15
Service
If you need technical support from company INDUTHERM, we’d like
to have
followinginformation
of your machine at first contact:
Service No. M17999 F below mains switch or
Serial number M17999 from identification plate at machine back-
side.