Operation
s [email protected] | roma noff.com
7-18
Figure 24: granulating insert
Take out insert.
Pour out the water.
Take out material.
7.11
Error diagnosis
There two types of disturbances.
Error and
warnings.
If there is an error, the heating will be stopped and there is shown an
error code in display.
With light disturbances there is only a warning in display.
7.12
Troubleshooting
The machine may be opened only by an expert.
Disturbance
Reason
Machine can’t be
switched on.
Mains voltage missing.
Heating don’t work.
Cooling water supply not switched on („E010)“.
Compressed air supply not switched on („E011“).
Protective gas supply not switched on („E013“).
Thermocouple not put in or faulty („0FbE“).
Generator overheated (too hot, „E021“).
Another error („Exxx“).
Temperature indication
not right.
Wrong thermocouple adjusted, see annexe.
Thermocouple faulty („E041“).
Because of this the generator can switch off!
Low generator output
Set value of temperature regulator too low.
Bad pressure build
up/release („E081“)
Bad flask sealings.
Dirty flange of flask.
With vacuum (vacuum supply faulty).
Bad vacuum at flask
(„E082“)
Bad flask sealing.
Dirty flange of flask.
Vacuum supply faulty.
Filter of vacuum pump is dirty.
If you have additional error messages Exxx, Then please see last pages of software
documentation in annexe.