10
IVEX Series Explosion Proof Camera Manual
Mounting and fixing to the pole
•
Using the provided hexagon bolt SET, fasten the bolt to
the bolt hole between the pole bracket and the product.
•
At this time, check that there are no foreign substances in the
thread or the product's fastening hole.
•
Before tightening the bolt, apply enough locking compound
(Loctite 263, medium-strength thread locker) to the bolt hole.
•
The thread compound should solidify for an hour,
during which time the installation should be completed.
•
When tightening the bolts, tighten the torque to 35Nm.
Before proceeding with the installation of the product, carefully read the
chapter'Safety Rules' in the product manual.
Fixed to vertical wall
•
The wall mount bracket can be fixed to a vertical wall.
•
Fix the bracket to the wall with the provided set anchor that
can withstand at least 4 times the weight of the device.
Then use the provided hexagon bolt SET to fix the device
to the bracket.
•
At this time, check that there are no foreign substances in the thread
or the product's fastening hole..
•
Apply enough locking compound (Loctite 263) on the two screws
and lock the screws.
•
The thread compound should solidify for an hour,
during which time the installation should be completed.
•
When tightening the bolt, tighten the torque to 35Nm.
Set anchor
Bracket from top to bottom
Precautions before installation