Industrial Shields PLC 10 Manual Download Page 5

Ref.

 

013001000100   

 

 

 

 

 

     Rev.1: 18-01-2021       

 

 

or  electric  control  room  should  be  limited  to  authorized  personnel.  Failure  to  follow 
these installation requirements could result in severe personal injury and/or property 
damage. Always follow these requirements when 10 I/Os family PLCs. 

 

In  case  of  installation  or  maintenance  of  the  10  I/Os  please  follow  the  instructions 
marked in the Installation and Maintenance section. 

 

Do  not  disconnect  equipment  when  a  flammable  or  combustible  atmosphere  is 
present. Disconnection of equipment when a flammable or combustible atmosphere is 
present may cause a fire or explosion which could result in death, serious injury and/or 
property damage. 
 
 

   

Avertissements: 

 

 

Les  broches  non  utilisées  ne  doivent  pas  être  connectées.  Ignorer  la  directive  peut 
endommager le contrôleur. 

 

Une utilisation incorrecte de ce produit peut endommager gravement le contrôleur. 

 

Reportez-vous  au  Guide  de  l

utilisateur  du  contrôleur  pour  les  considérations  de 

câblage. 

 

Avant d

utiliser ce produit, il incombe à l

utilisateur de lire le Guide de l

utilisateur du 

produit et la documentation qui l

accompagne. 

 

La  maintenance  doit  être  effectuée  par  personnel  qualifié  familiarisé  avec  la 
fabrication, le fonctionnement et les dangers liés au contrôleur. 

 

La maintenance doit être effectuée avec l

’é

quipement hors service et déconnectée de 

toutes les sources d'alimentation. 

 

Faites  attention  lors  de  l'entretien  des  composants  sensibles  à  l'électricité  statique. 
Les recommandations du fabricant pour ces composants doivent être suivies. 

 

Les  automates  de  la  famille  10  I/Os  sont  des  contrôleurs  de  type  ouvert.  Il  est 
nécessaire d'installer l'automate 10 I/Os dans un boîtier, une armoire ou une salle de 
contrôle  électrique.  L'accès  au  boîtier,  à  l'armoire  ou  à  la  salle  de  commande 
électrique  doit  être  limité  au  personnel  autorisé.  Le  non-respect  de  ces  exigences 
d'installation  peut  entraîner  des  blessures  graves  et/ou  des  dommages  matériels 
importants. Respectez toujours ces exigences lors de l'installation des automates de la 
famille 10 I/Os. 

 

En  cas  d'installation  ou  de  maintenance  du  10  I/Os,  veuillez  suivre  les  instructions 
indiquées dans la section Installation et Maintenance. 

 

Ne  débranchez  pas  l'équipement  en  présence  d'une  atmosphère  inflammable  ou 
combustible.  La  déconnexion  de  l'équipement  en  présence  d'une  atmosphère 
inflammable  ou  combustible  peut  provoquer  un  incendie  ou  une  explosion  pouvant 
entraîner la mort, des blessures graves et/ou des dommages matériels. 
 

Summary of Contents for PLC 10

Page 1: ...PLC 10 I Os DIGITAL MODULE CPU ARDUINO NANO PLC 10 I Os DIGITAL MODULE CPU ARDUINO NANO...

Page 2: ...Ref 013001000100 Rev 1 18 01 2021 1...

Page 3: ...100 Rev 1 18 01 2021 2 PLC 10 I Os Digital Module CPU ARDUINO NANO User Guide Revised September 2020 This user guide is for version PLC 10 I Os Digital Module CPU ARDUINO NANO with Reference name Ref...

Page 4: ...ing the directive may damage the controller Improper use of this product may severely damage the controller Refer to the controller s User Guide regarding wiring considerations Before using this produ...

Page 5: ...e effectu e par personnel qualifi familiaris avec la fabrication le fonctionnement et les dangers li s au contr leur La maintenance doit tre effectu e avec l quipement hors service et d connect e de t...

Page 6: ...any codes regulations or standards that apply to the combination of products in the customer s application or use of the product The following are some examples of applications for which particular a...

Page 7: ...ze risks resulting from the handling or manipulation of such products systems and to avoid possible hazards Disclaimers Weights and Dimensions Dimensions and weights are nominal and they are not used...

Page 8: ...nts during commissioning operation maintenance and repairs caused by for example Hardware defects and or software errors in the sensors controllers actuators and connection technology Response times o...

Page 9: ...ED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE INDUSTRIAL SHIELDS DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED Limitations of Liability INDUSTRIAL SHIELDS SHALL NO...

Page 10: ...are Interface 14 5 How to connect PLC ARDUINO NANO to PC 17 6 How to connect PLC to power supply 18 7 10 I Os Digital Module pinout 19 Left Zone Connections 19 Right Zone Connections 20 Top Zone Conne...

Page 11: ...Power 30 W I Max 1 5A Size 100x45x115 Clock Speed 16 MHz Flash Memory 32KB of which 2KB are used by bootloader SRAM 2 KB EEPROM 1 KB Communications USB RS485 ETH MAX487CSA W5500 USB Consideration Only...

Page 12: ...l the external AC terminals and the protective earth terminal Shock resistance 80m s2 in the X Y and Z direction 2 times each Ambient temperature operating 0 to 60 C Ambient humidity operating 10 to 9...

Page 13: ...g current only to identify relevant terminals IEC 60417 Graphical symbols for use on equipment 5130 Pulse General To identify the control by which a pulse is started IEC 60417 Graphical symbols for us...

Page 14: ...cations described in this manual Before using 10 I Os Digital Module CPU ARDUINO NANO under different conditions from what has been specified in this manual or integrating 10 I Os Digital Module CPU A...

Page 15: ...h easier Basically it is no needed to define the pins and if that pins are inputs or outputs Everything is set up automatically if using the boards In order to install Industrial Shields boards these...

Page 16: ...Ref 013001000100 Rev 1 18 01 2021 15 4 Go to Tools Board Boards Manager 5 Search for industrialshields megaavr on the browser 6 Click install industrialshields megaavr selecting the latest version...

Page 17: ...d 10 IOs PLC Family an extra option will appear on Tools There it can be selected the exact model for every family In this case 10 IOS PLC Also there are some examples of programming in File Examples...

Page 18: ...t PLC ARDUINO NANO to PC Connect USB port from PLC to PC NOTE 10 I Os Family uses micro USB cable Open Arduino IDE interface Select Industrial Shields megaAVR boards 10 IOS PLC Family Select the corre...

Page 19: ...ies regardless of where use of the device is intended The equipment must be powered from an external power source in accordance with IEC 61010 1 whose output is MBTS and is limited in power according...

Page 20: ...Pin Function Q 0 9 Q 0 8 Q 0 7 Q 0 6 Q 0 5 Q 0 4 Q 0 3 Q 0 2 Q 0 1 Q 0 0 D9 D6 D5 D3 D2 A6 A3 A2 A1 A0 Digital Output Digital Output Digital Output Digital Output Digital Output Digital Output Digital...

Page 21: ...0 9 I 0 8 I 0 7 I 0 6 I 0 5 GNDCOM2 I 0 4 I 0 3 I 0 2 I 0 1 I 0 0 GNDCOM1 D9 D6 D5 D3 D2 A6 A3 A2 A1 A0 Digital Input Digital Input Digital Input Digital Input Digital Input Ground Digital Input Digit...

Page 22: ...EDs positioned at the top of the PLC which go from led 0 to 9 refer to both inputs and outputs For example if you are using input I0 9 LED 9 on the top cover of the PLC will indicate the signal status...

Page 23: ...ts There is a Jumper Zone 1 with three pins on each side of the board In the case of using the pins as Inputs the jumper must be connected on the pins 1 and 2 Otherwise if the pin is wished to work as...

Page 24: ...age the device and could burn it This jumper zone makes the choosing between a 5V and 24 V The 24V option will be used in the case of using the pins as OUTPUT as it will provides the same voltage as t...

Page 25: ...Ref 013001000100 Rev 1 18 01 2021 24...

Page 26: ...Ref 013001000100 Rev 1 18 01 2021 25 I Os Configuration examples Input mode Low voltage This is an exemple to configure 0 9 as an input with the 3 3 24V current range...

Page 27: ...Ref 013001000100 Rev 1 18 01 2021 26 High voltage This is an exemple to configure 0 9 as an input with the 230V current range...

Page 28: ...Ref 013001000100 Rev 1 18 01 2021 27 Output mode Low voltage This is an exemple to configure 0 9 as an output with the 3 3 24V current range...

Page 29: ...C of the connection between Arduino NANO pins the RS 485 chip and its outputs Using the boards of Industrial Shields there is a library that simplifies the RS 485 implementation Ethernet 10 I Os Ether...

Page 30: ...Ref 013001000100 Rev 1 18 01 2021 29 10 Typical Connections 3 3 24v...

Page 31: ...nnection details Article reference MC 0 5 6 G 2 5 THT Height 8 1mm Pitch 2 5mm Dimension 22 5mm Pin dimensions 0 8x0 8mm Pin spacing 2 50mm Article reference M1 5 6 G 3 81 Height h 10 65mm Pitch 3 81m...

Page 32: ...Ref 013001000100 Rev 1 18 01 2021 31 12 10 I Os Family Dimensions 45mm width DIN rail mounting...

Page 33: ...ocation has high ambient temperature or heat generating equipment nearby install forced convection devices on top or sides of the cabinet to avoid over temperature During drilling or wiring prevent th...

Page 34: ...be checked to assure its integrity Accumulations of dust and dirt on all parts including on semiconductor heat sinks should be removed according to the manufacturer s instructions if provided otherwi...

Page 35: ...ing can damage the screws and or the module with the risk of falling short circuits and malfunctions Before handling a module dispose of the electrostatic charge accumulated by the human body by touch...

Page 36: ...Ref 013001000100 Rev 1 18 01 2021 35 14 Revision Table Revision Number Date Changes 0 14 09 2020 First implementation 1 18 01 2021 Added Software Section 4...

Page 37: ...01 2021 36 About Industrial Shields Direction F brica del Pont 1 11 Zip Postal Code 08272 City Sant Fruit s de Bages Barcelona Country Spain Telephone 34 938 760 191 34 635 693 611 Mail industrialshie...

Reviews: