background image

FGR-ST-DL210A Fingerprint Door Lock
Deadbolt User Manual V4.0

6. Registering or Enrolling Fingerprints

Access to Exterior and Interior lock portion are needed

Exterior Side - 

slide up the dust cover and push the 

“Power On”

button and to scan your fingerprints.

Interior Side -

you will be using the 

STOR, DEL

and  

(Select)

buttons.

A. In order to register or enroll a user fingerprints, you will be operating buttons on the interior

portion and using the scanning window on the Exterior portion, thus both sides of the lock will
be used. Please familiarize yourself with the location of buttons as shown in these pictures,
as well as the sequence of operations, in order for you to more easily accomplish the
registration without being "timed out". 

B.

For the first two registrations, there is no need to assign management levels as they
will be Administrators automatically

, but on subsequent registrations, have in mind what

authorization level you wish to assign and the range of template ID numbers defining the
levels. Make sure your selection is correct using the form provided.

Guardian DL210A Operation Manual V4.0                      © Copyright 2004 Index Security Inc.

9

Index

Access

Exterior

portion

Interior

portion

Power
Button

Summary of Contents for FGR-ST-DL210A

Page 1: ...FGR ST DL210A Fingerprint Door Lock Deadbolt User Manual V4 0 Guardian DL210A Operation Manual V4 0 Copyright 2004 Index Security Inc 1 Index Access ...

Page 2: ...Access 15 11 Specifications 16 12 Troubleshooting 17 13 Warranty Policy 19 14 Warranty Card 21 15 User ID List 23 Your Guardian 210A is a product of superior design and craftsmanship from the Technology Makers of Index security Inc Proper placement and care should be given to insure the use of this product for many years This is not an outdoor device it is not water proof and should be installed i...

Page 3: ...nstall the Unit manual if needed 4 Determine who the administrator is for the lock The first two people Registered will be automatically assigned Administrator IDs 5 Outline all Users on the Fingerprint Template ID form for tracking user ID number positions Install Batteries 1 Six 6 alkaline AA batteries are needed To change batteries remove the battery cover by pulling it straight out from both s...

Page 4: ...Button Emergency Key for Deadbolt Protective Cover slides upward Deadbolt Lock Button Emergency Key For Lower Cylindrical Lock Under Cap Optical Fingerprint Scanner LED Display Deadbolt Unlock Deadbolt Lock Emergency Deadbolt Key STOR DELETE Battery Compartment 6 AA alkaline batteries SELECT 1 Specification Callout s Exterior portion Interior portions Power Button ...

Page 5: ...n the door without engaging the fingerprint identification system E Sensitivity Levels Five sensitivity settings are available to optimize scan sensitivity in matching fingerprint images The lower levels the easier it is for acceptance and the higher captures more of the fingerprint to verify and is more secure F Management Levels The Guardian 210A has three authorization category levels Administr...

Page 6: ...programming function such as registering fingerprints B When in the Programming Mode immediately after registering fingerprints you can press the Select button and see the NEXT AVAILABLE ID or template position of the three categories of user rights Administrator Supervisor or User For example if you have two 2 Administrators and three 3 Users already registered and you just finished adding a four...

Page 7: ...FGR ST DL210A Fingerprint Door Lock Deadbolt User Manual V4 0 Guardian DL210A Operation Manual V4 0 Copyright 2004 Index Security Inc 7 Index Access 4 How to Scan Your Fingerprint ...

Page 8: ... the security level increases A If no fingerprints have been registered press Power button on Exterior portion hear 2 beeps B Press STOR DEL and Select buttons on interior display panel simultaneously until the display shows 00 or S0 S1 S2 S3 or S4 Highest level C Release the three buttons then press the Select button to cycle through S0 S1 S2 S3 S4 etc D Training Set at S0 to start training which...

Page 9: ...s of the lock will be used Please familiarize yourself with the location of buttons as shown in these pictures as well as the sequence of operations in order for you to more easily accomplish the registration without being timed out B For the first two registrations there is no need to assign management levels as they will be Administrators automatically but on subsequent registrations have in min...

Page 10: ...long beep sounds again and scanner starts scanning your finger E When scanner goes off and a short beep sounds pick up and replace the same finger firmly for a second scan which starts automatically F When TWO short beeps sound congratulations Your fingerprint was successfully registered G If you hear THREE beeps the fingerprint was NOT registered due to a poor image movement or other reasons Star...

Page 11: ... to set the sensitivity level might make it easier or harder and how to trade off ease of acceptance with tight security E Helpful Hint If you have difficulty activating the lock and your rejection rate is more than half the time consider re registering of your fingerprint with a different finger more pressure different position etc If you had successfully registered your fingerprint but cannot op...

Page 12: ...the Supervisor level for example you would cycle the three available choices to 06 the next available ID number in the Supervisor category Note The template ID number must be selected at this time A fingerprint image cannot have its management level changed after registering F As you register each person keep record of their assigned s this way if you wish to delete an individual at a later time i...

Page 13: ...an two fingerprints registered A One of the Administrators must first perform an unlocking procedure B Immediately after the Administrator is successfully verified press the Select button once and release then press both DEL and STOR buttons simultaneously for about 3 seconds Display will show UU Deleting individual fingerprints A Administrators can delete anyone Supervisors can delete IDs on the ...

Page 14: ...Button and is not automatic from the Exterior body or when outside Inside Door Operation There re two 2 locking points The Lower Cylindrical Lock and Dead Bolt For your understanding The cylindrical lower lock is unlocked by pulling down on the handle when exiting from the inside Interior Dead Bolt Locking There are Lock and Unlock buttons clearly marked on the inside of the lock which apply only ...

Page 15: ...s not functioning B The same Emergency key is used for the Deadbolt and the Lower Cylindrical lock Both keyholes are normally hidden from view and are accessed only from the Outside C For the Dead Bolt slide up dust cover and then remove it completely to expose the keyhole Cover pops off by pulling upwards D For the lower cylindrical lock use a pocket knife or tiny screw driver to pry off the roun...

Page 16: ...he lock is unlocked and while power is still on press the Select button TWICE then press the Unlock button A long beep will sound and the lock will remain unlocked B To return to normal operation press Lock button inside or outside 11 Specifications Guardian DL210A Operation Manual V4 0 Copyright 2004 Index Security Inc 16 Index Access ...

Page 17: ...ng a good image The batteries are depleted low voltage signal sounds Solution Repeat the procedure but put finger on more quickly Repeat the procedure and vary the positioning of the finger If registering try a different finger If unlocking clean finger Change batteries Possible Cause The batteries are depleted low voltage signal sounds The batteries were not installed correctly Solution Change ba...

Page 18: ...ss Possible Cause Levels were not set up before registration Solution Delete and Re register incorrect fingerprints with proper management levels selected prior to scanning of fingers or Delete all fingerprints and re register everyone 500 Parker Avenue Suite G Deal New Jersey 07723 1435 Phone 732 531 9209 Fax 732 531 2307 Toll Free 866 INDEX89 866 463 3989 www index security com info index securi...

Page 19: ...31 2307 Make sure to put the Serial number on the form You must register to validate this warranty within 30 days of purchase If during the warranty period the product fails due to defects in materials or workmanship you may request an RMA via the web site phone or by fax and after receiving an RMA you can return the defective product freight pre paid to Guardian c o Index Security Inc 500 Parker ...

Page 20: ...FGR ST DL210A Fingerprint Door Lock Deadbolt User Manual V4 0 Notes Guardian DL210A Operation Manual V4 0 Copyright 2004 Index Security Inc 20 Index Access ...

Page 21: ...FGR ST DL210A Fingerprint Door Lock Deadbolt User Manual V4 0 Guardian DL210A Operation Manual V4 0 Copyright 2004 Index Security Inc 21 Index Access 14 Warranty Card ...

Page 22: ...FGR ST DL210A Fingerprint Door Lock Deadbolt User Manual V4 0 Guardian DL210A Operation Manual V4 0 Copyright 2004 Index Security Inc 22 Index Access ...

Page 23: ...23 Index Access ID Name ID Name ID Name Admin 1 20 39 Admin 2 21 40 Admin 3 22 41 Admin 4 23 42 Admin 5 24 43 Supervisor 6 25 44 Supervisor 7 26 45 Supervisor 8 27 46 Supervisor 9 28 47 Supervisor 10 29 48 User 11 30 49 User 12 31 50 User 13 32 User 14 33 User 15 34 User 16 35 User 17 36 User 18 37 User 19 38 15 USER Template ID LIST ...

Reviews: