FGR-ST-DL210A Fingerprint Door Lock
Deadbolt User Manual V4.0
Guardian DL210A Operation Manual V4.0 © Copyright 2004 Index Security Inc.
6
Index
Access
Action
Mass erase
Add same level
Delete same level
Add below level
Delete below level
Open door
Check current ID
Administrator
IDs: 1 - 5
X
X
X
X
X
X
X
Supervisor
IDs: 6 - 10
X
X
X
X
User
IDs: 11 - 50
X
X
CHART:
Management Levels
3. LED Display
The display shows three types of information:
• Memory status: UU = memory is empty; FU = memory is full (has all 50 users registered)
• Sensitivity (Security) level: S0 through S4
• Template IDs assigned positions
Display Template ID Position
A. The LED displays different information
depending on if you are in a pure display mode or if you have just finished a programming
function such as registering fingerprints.
B. When in the Programming Mode, immediately after registering fingerprints, you can press the
Select button and see the NEXT AVAILABLE ID or template position of the three categories of
user rights: Administrator, Supervisor or User. For example, if you have two (2) Administrators
and three (3) Users already registered and you just finished adding a fourth (4) User, pressing
the Select button will show: 15 - 3 - 5
C. In the normal Display mode, you can verify the ID of the person who just unlocked the lock.
Immediately after fingerprint verification, press the Select button. The Display will then show
the entering ID, alternating with the remaining number of available spaces in the lock
memory. For example, if there are two (2) Administrators and the last of four (4) Users just
entered, the display would show: 04 - 44
D. Memory status:
UU
= memory is empty;
FU
= memory is full (has all 50 users registered)