10
GB
Table of burner and nozzle specifications
S S
R
A
Table1 (for Poland)
G20 (GZ50)
G2.350 (GZ35)
G30 (GPB)
Burner Diameter
(mm)
Thermal
Power
kW (p.c.s.*)
Nozzle
1/100
(mm)
Flow*
l/h
Nozzle
1/100
(mm)
Flow*
l/h
Thermal
power
(p.c.i.*)
kW
Dysza
1/100
(mm)
Flow*
g/h
Fast (Large)(R)
100 3,00 128
286
158
397 3,40
87
247
Semi Fast
(Medium)(S)
75
1,90 104 181 143 251 2,20 70 160
Auxiliary (Small)(A)
51
1,00
76 95 106
132 1,30 52 95
Supply Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
16
20
25
10
13
16
29
37
44
* A 15°C 1013 mbar dry gas
G20 (GZ50) p.c.i. = 37,78 MJ/m³
G2.350 (GZ35) p.c.i. = 27,20 MJ/m³
G30 (GPB) p.c.i. = 125,81 MJ/m³
TECHNICAL DATA
Oven dimensions
(HxWxD)
Volume
61 l
Useful
measurements
relating to the
oven
compartment
width 42 cm
depth 44 cm
height 17 cm
Power supply
voltage and
frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven compartment
has been opened, on the left-hand
wall inside the oven.
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens. Standard EN
50304
Declared energy consumption for
Natural convection Class – heating
mode:
Static
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments -
90/369/EC dated 29/06/90 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments -
2002/96/EC.
1275/2008 (Stand-by/Off mode)
(x)
Data plate, is located inside the flap or, after the oven
compartment has been opened, on the left-hand wall
inside the oven.
I5NSH1AE U
I5GSHA U
S
R
ø 145
ø 180
340x391x455 mm