![background image](http://html1.mh-extra.com/html/imv/vm-5011a/vm-5011a_instruction-manuals_2050066018.webp)
-
18
-
VM-5011A Instruction Manuals
(TVE-6-4188E / Version 1.20)
Appendix.1 How to connect with VP-8021A
Converter also supports connection with our MEMS high-frequency vibration sensor VP-
8021A.
Factory default connection sensor is set to VP-100. When connecting VP-8021A to
converter, it is necessary to change jumper JP4 settings on circuit board (see Fig.A-1).
Fig.A-1 Jumper change when connecting VP-8021A
Refer to "5. Wiring method" for how to connect the VP-8021A to the converter.
Memo
(1) Refer to "7. Change of Measurement Range and DC Output" for how to pull out the
board.
(2) For more information on VP-8021A, please check our website.
URL: https://www.imv.co.jp
JP4
3
2
1
Factory Default
(VP-100)
3
2
1
Settings when
connecting
VP-8021A
When connecting VP-8021A to
converter, change the jumper of JP4
between 2-3.
Enlarged View of JP4