background image

 
 

  12 

 

VM-5011A Instruction Manuals 

(TVE-6-4188E / Version 1.20) 

 

10. Specifications

 

10-1. Specifications of Converter (VM-5011A) 

Model 

VM-5011A 

Input Range 

0

500m/s

2

 

Measuring Range of 

Frequency 

E acceleration  10Hz to 1kHz 

Band Pass Filter: 500Hz

10kHz 

See “10-2. Standard Characteristic of Converter” 

Velocity 

10Hz to 1kHz 

(ISO 2954:2012 Filter Characteristics compliant) 

See “10-2. Standard Characteristic of Converter” 

Measuring Range (*) 

E acceleration 

  10m/s

2

E rms 

  25m/s

2

E rms 

  50m/s

2

E rms 

  100m/s

2

E rms 

Velocity 

  10mm/s rms 

  25mm/s rms 

  50mm/s rms 

  100mm/s rms 

Connect Sensor (*) 

  VP-100 

  VP-8021A 

DC Output (*) 

E acceleration 

  4-20mA (Load 500

Ω

  or lower) 

  0-10V (Load 100k

Ω

 or higher)

 

Velocity 

  4-20mA (Load 500

Ω

  or lower) 

  0-10V (Load 100k

Ω

 or higher) 

AC Output 

E acceleration  0-1Vrms (Load 100k

Ω

  or higher) 

Velocity 

0-1Vrms (Load 100k

Ω

  or higher) 

Linearity 

DC Output 

within  ±3%F.S 

AC Output 

within  ±5% 

Sensor Waveform Output 

Depends on Sensor Voltage Sensitivity 

Bias Voltage: 9VDC 

Operating Temperature 

and Humidity Range 

0 to 50

℃、

95%RH or less 

without freezing or condensation 

Suitable Cable of Terminal Block 

0.2 to 2.5mm

2

 (Single wire / Stranded wire) 

(AWG12 to 24) 

Power Supply of Converter 

DC24V±10% 

Power Supply of Sensor 

DC24V  3.5mA±20% 

Power Consumption 

3W or less 

Case Material 

Resin 

Outer Dimensions (Excluding protrusions)  W22.6×H99×D113.6mm (See p.13) 
Weight 

Approx. 150g 

*  ”

”  is factory default settings. 

 

 

Summary of Contents for VM-5011A

Page 1: ...ction Manuals TVE 6 4188E Version 1 20 Instruction Manuals of Signal Converter Detailed Edition MODEL VM 5011A Manufacturer IMV CORPORATION Document No TVE 6 4188E Created Date 8th April 2021 Version...

Page 2: ...DC Output 8 Handling precautions 9 Warranty 10 Specifications 10 1 Specifications of Converter VM 5011A 10 2 Standard Characteristic of Converter 10 3 Outer dimensions of Converter 10 4 Specifications...

Page 3: ...harm to customers and other people and damage to property and to use this product safely Please be sure to read this instruction manuals and attached documents before use and fully understand the con...

Page 4: ...ized do not touch the terminal block etc carelessly Note 1 When connecting sensor to converter check the method that matches the specifications of the device to be connected Improper connection may ca...

Page 5: ...veforms 2 Features 1 Simultaneous monitoring of E acceleration and velocity levels 2 Sensor has a drip proof structure 3 Converter is compact and can be mounted on a DIN rail 3 System Composition 3 1...

Page 6: ...nt to be measured grounded If sensor mounting surface measurement target instrument is not properly grounded sensor may become charged and may fail 2 Is the sensor mounting surface cleanly finished Co...

Page 7: ...power line as possible 2 To protect the sensor cable from vibration use a flexible conduit up to the sensor installation location 3 When relaying sensor cable using junction box install it in an envir...

Page 8: ...Sensor Input Shield Wire Not Normally Use FG 2 3 4 Sensor Waveform Output Sensor Waveform Output Power 24VDC Power 24VDC AC Output Velocity AC Output E acceleration DC Output Velocity DC Output E acc...

Page 9: ...tput Converter can change measurement range and DC output Follow the procedure below Setting Method 1 Turn off power supply to converter and disconnect all wiring connected to converter 2 Remove the t...

Page 10: ...turn on more than one switch Fig 7 2 Setting of Measurement Range and DC Output Note 1 Do not change jumper or adjust variable resistance other than the above Correct measurement may not be possible 2...

Page 11: ...ct is shipped after the strict inspection in our factory But in case the system has the fault caused by the responsibility of IMV as the defect under production and material during warranty period we...

Page 12: ...C Output E acceleration 4 20mA Load 500 or lower 0 10V Load 100k or higher Velocity 4 20mA Load 500 or lower 0 10V Load 100k or higher AC Output E acceleration 0 1Vrms Load 100k or higher Velocity 0 1...

Page 13: ...9 10 25 50 100 10 25 50 100 QC Pass VM 5011A Power IEPE Sensor signal converter Unit mm 50 40 30 20 10 0 10 10 100 1000 10000 100000 Response dB Frequency Hz Env Acc Firststage filter characteristics...

Page 14: ...Voltage Sensitivity 10 2mV m s2 10 Max Measurement Acceleration 784m s2 Sensor Drive Current 0 5 to 8mA 18 to 30VDC Operating Temperature 55 to 140 Protection Class IP65 Weight Approx 125g without Ca...

Page 15: ...e 10Hz to 8kHz 3dB Voltage Sensitivity 3 9mV m s2 5 Max Measurement Acceleration 490m s2 Sensor Drive Current 3 5mA Typ DC24V Max Operating Temperature 30 to 120 Weight Approx 15g Case Material A5052...

Page 16: ...ply power Cable connection is not made or cable connection is incorrect Make sure to connect them securely The supply power supply voltage is out of the specification range Check the power supply spec...

Page 17: ...hey are removed in advance using a bandpass filter This product uses a bandpass filter of 500Hz to 10kHz before envelope processing removes primary rotation components and low frequency components per...

Page 18: ...r JP4 settings on circuit board see Fig A 1 Fig A 1 Jumper change when connecting VP 8021A Refer to 5 Wiring method for how to connect the VP 8021A to the converter Memo 1 Refer to 7 Change of Measure...

Page 19: ...round it via converter as shown in Fig A 2 1 2 3 4 5 6 7 8 IEPE Sensor signal convector Sensor Ground terminal 4 Fig A 2 Wiring when sensor is not grounded Memo If the location where sensor is install...

Page 20: ...y with jumper JP3 see Fig A 3 Fig A 3 Sensor drive current supply setting Memo 1 Refer to 7 Change of Measurement Range and DC Output for how to pull out the board 2 In the case of voltage input conne...

Page 21: ...at the same time see Fig A 4 1 VM 5011B 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 Power IEPE Sensor Power 24VDC 1 VM 5011A 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 Power IEPE Sensor Connection Setting Voltage...

Page 22: ...t mm Cautions The adsorption force of magnet is very strong even if it is installed to the sensor mounting surface from a very short distance a large impact will be applied to the sensor Sensor may br...

Reviews: