VM-3024S/H Instruction Manual
(Compatible with Version 2.16 or later)
AC output sensitivity specifies the full scale for the ACOUT voltage value. Touching the
“Set” button will display Fig.4-12.
For each of velocity, acceleration, and displacement, set the value of voltage 1V.
In the example shown in Fig.4-12, the settings are as follows.
Vel.: “1V” is equivalent “200mm/s EQP”
Acc.: “1V” is equivalent “100m/s
2
EQP”
Disp.: “1V” is equivalent “500
μ
mo-p”
(Japanese)
(English)
Fig.4-12 AC Output Sensitivity Setting Page
On the other hand, DC output sensitivity specifies the full scale for the DCOUT voltage
value.
Touching the “Set” button will display Fig.4-13.
(Japanese)
(English)
Fig.4-13 DC Output Sensitivity Setting Page
1V