IMV SmartVibro VM-3024H Instruction Manual Download Page 1

 

 

 

1

 

 

VM-3024S/H Instruction Manual 

(Compatible with Version 2.16 or later) 

 
 
 
 
 
 
 
 

Instruction Manual 

 

Portable Vibrometer 

SmartVibro Series 

 

Model: VM-3024S 

          VM-3024H 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Manufacture: 

IMV CORPORATION

 

Document No.:  TVE-6-3790E 
Revision Date:  18

th

 June, 2021 

Page: 

 

44 

Revision:  

3.0.0 

 

 

Summary of Contents for SmartVibro VM-3024H

Page 1: ...nual Compatible with Version 2 16 or later Instruction Manual Portable Vibrometer SmartVibro Series Model VM 3024S VM 3024H Manufacture IMV CORPORATION Document No TVE 6 3790E Revision Date 18th June...

Page 2: ...24 28th Jan 2016 1 5 3 Corrected AC Adapter Model Number 10th May 2016 2 0 0 1 Ver2 00 and overall review 2 SmartVibro screen and wording were corrected 18th June 2021 3 0 0 1 Ver2 16 or later compati...

Page 3: ...ing of Battery Type 22 4 5 2 Setting of Auto Power Off Function 22 4 5 3 Setting of Contrast 22 4 6 Language Setting 23 4 6 1 Language Setting 23 4 6 2 Version Information 24 4 7 Password Function 25...

Page 4: ...moving element the mounting of pick up please go to when the machine is stopped In such a place measuring the vibration with pick up in one s hand it causes burn injury and cable engulfment It is very...

Page 5: ...elow High end model has these two icons when the machine is turned on VM 3024 can be switched freely between Japanese and English Standard Model VM 3024S Japanese English High End Model VM 3024H Japan...

Page 6: ...ecorder etc Battery 1 AA Alkaline Batteries Instruction Manuals 1 with Inspection Sheet SD Card 1 VM 3024H only 2 Option Accessories Products Model Note Figure 1 Long Pickup Cable CE 3024 3 3m CE 3024...

Page 7: ...or Standardization ISO2954 is available from ISO website https www iso org home html 2 2 Features Frequency Range 10Hz to 1kHz Simultaneous Measurement High speed processing CPU enabled simultaneous d...

Page 8: ...CD Panel Displays and sets measured values Function Button Displays the setting screen range screen during measurement etc Measurement Button Starts Stops measurement SD Card Slot Waveform data storag...

Page 9: ...t of the vibration severity velocity setting needs to be rms 2 Check the polarity carefully and set two AA batteries in the battery box Ni Cd or Alkaline Fig 3 2 For the use with the AC adaptor connec...

Page 10: ...ta The data is not absolute but rough indication 3 Function Indicator Valid functions are indicated In Fig 3 3 Start and Setting are operative 4 Battery Indicator This appears when the battery level i...

Page 11: ...F refer to section 4 4 the range key will be activated during measurement Fig 3 4 Touching Range on the touch screen or pressing Function Button will show the range setting display You may adjust the...

Page 12: ...m in the image Fig 3 4 To zoom out touch the same area again Fig 3 6 Japanese English Fig 3 5 Display during Changing the Range Japanese English Fig 3 6 Enlarged Touch here to zoom out Range Up Range...

Page 13: ...ngs such as measurement mode As shown in Fig 4 1 the setting screen will appear when pressing Function Button or touching Setting on the touch screen when setting is indicated in the function indicato...

Page 14: ...l Compatible with Version 2 16 or later The setting screen can be switched by touching the icon at the top of the screen Fig 4 3 Japanese English Fig 4 3 Switching the setting screen Switching is in t...

Page 15: ...Also the enlarged screen will show the physical amount accordingly Japanese English Fig 4 4 Mode Setting In Mode the setting mode changes in the following order each time the button is touched After s...

Page 16: ...o indicate the physical amount of measurement results in calculation setting Calc As you touch Set in Fig 4 2 Fig 4 6 will appear Japanese English Fig 4 6 Calculation Setting The calculation method se...

Page 17: ...hich is also known as vibration severity EQP EQP is a value gained by rms 2 This formula is suitable to use for measurement of sine vibration generated by rotational machines for example Peak The maxi...

Page 18: ...ting Page of Auto Range When auto range is ON range will be adjusted automatically during measurement Fig 4 8 Range will not be indicated on the measurement display In this case Function Button is not...

Page 19: ...g 4 12 to move to the second page There are 4 pages in total and every time you touch Next Page the screen is change as follow 1page 2page 3page 4page 1page For the contents on 2page and after refer t...

Page 20: ...the value of voltage 1V In the example shown in Fig 4 12 the settings are as follows Vel 1V is equivalent 200mm s EQP Acc 1V is equivalent 100m s2 EQP Disp 1V is equivalent 500 mo p Japanese English...

Page 21: ...o Range is set to ON the vibration value fluctuates greatly immediately after when the measurement range switched At this time AC output and DC output fluctuate greatly and correct measurement results...

Page 22: ...are used the battery life may not be indicated correctly 4 5 2 Setting of Auto Power Off Function When Auto Power Off is set to ON the power is automatically turned off approximately 10 minutes after...

Page 23: ...on the setting screen shown in Fig 4 15 to move to the third page Fig 4 16 Japanese English Fig 4 16 Language Setting and Version Information 4 6 1 Language Setting Select en for English Once you res...

Page 24: ...ersion Touch the View button next to the version in Fig 4 16 to display the version information Fig 4 17 Japanese English Fig 4 17 Display of Version If you contact us about the product we may check t...

Page 25: ...set so that only the administrator can change the settings Note that the password is not set when shipped from the factory OFF Japanese English Fig 4 18 Password Setting Password OFF Push the OFF butt...

Page 26: ...26 VM 3024S H Instruction Manual Compatible with Version 2 16 or later Japanese English Fig 4 19 Password Input Japanese English Fig 4 20 Password Setting Password ON...

Page 27: ...r and press the return button If password is correct the setting page will be displayed If password is not correct then the Password entry is required again In such a case please confirm your password...

Page 28: ...or later 4 8 Battery Indicator When PwrInfo is displayed press Measurement Button or touch PwrInfo on the touch screen to check the power information Fig 4 22 and Fig 4 23 Japanese English Fig 4 22 Pw...

Page 29: ...he SD card as plain text Only waveform data can be saved to SD FFT results and measurement values OA values displayed on the screen cannot be saved About FFT Function and Waveform Saving Only VM 3024H...

Page 30: ...FT tab will show the screen Fig 5 2 Japanese English Fig 5 2 FFT Menu 1 FFT Graph Y axis shows the physical amount of the measurement result indicated above the graph Velocity in Fig 5 2 X axis indica...

Page 31: ...reen will move from one peak to another peak 2 MAX Maximum value of the gathered data Cur Value pointed by the cursor 3 Slide the cursor Regarding the Range when using FFT When Auto Range is set to OF...

Page 32: ...Page is touched the setting screen for Save Point and FFT Line is displayed Fig 5 4 FFT Line shows a frequency resolution You can select from 2 5Hz 5Hz and 10Hz Japanese English Fig 5 4 Setting of FFT...

Page 33: ...nual Compatible with Version 2 16 or later Japanese English Fig 5 5 Waveform Data Gathering Start Pressing Measurement Button or touching Start in Fig 5 5 starts gathering the data Japanese English Fi...

Page 34: ...ss Function Button or touch Save on the touch screen to save the data to SD Saving to SD is numbered in order starting from 0000 and saved to SD card Fig 5 8 1 To cancel during waveform acquisition pr...

Page 35: ...aveform data 3 If you move to waveform data save with a large amount of waveform data stored in SD it may take some time before waveform acquisition can be started To smooth the waveform data save del...

Page 36: ...fied is 1s 2s 5s and 10s The time changes each time you touch The number of data acquisitions is 10 240 per second and is proportional to the save point so calculate the time axis based on this see th...

Page 37: ...ion Manual Compatible with Version 2 16 or later 6 Conversion Table 104 1 Frequency Hz Displacement mmp p Acceleration m s2 1 10 102 10 1 10 2 10 3 1 10 102 103 10 1 10 2 Velocity mm s 103 102 10 1 10...

Page 38: ...anese or English Power Supply AA 2pcs Approx 20hrs in continuous run Alarm Icon in the screen Ambient Conditions Use Range 0 to 50 C 95 RH or less Accuracy Assured 5 to 35 C 85 RH or less Storage rang...

Page 39: ...39 VM 3024S H Instruction Manual Compatible with Version 2 16 or later 7 3 Outer Dimensions of SmartVibro 74 Unit mm 32 5 143 10 5...

Page 40: ...024S H Instruction Manual Compatible with Version 2 16 or later 7 4 Outer Dimensions of Pickup and Probe Pickup Probe Pickup Cable 1500 50 25 M6 P 1 depth7 Clump Filter 50 4 10 6 10 M6 P 1 R1 Cable Co...

Page 41: ...d DC output waveforms are greatly disturbed If Auto Range is set to ON the vibration value fluctuates greatly immediately after when the measurement range switched At this time AC output and DC output...

Page 42: ...hods include 1 Screw mounting 2 Instant adhesive 3 Double sided adhesive tape thin and strong material 4 Magnet and 5 pressed by hand Fig 10 1 The contact resonance frequency by these methods is above...

Page 43: ...ompatible with Version 2 16 or later Fig 10 2 Contact Resonance Response of Pickup 0 6 10 10 6 0 6 10 10 6 0 6 10 10 6 10 Frequency Hz 4 No Use Oil 3 1 2 Response dB 20 50 100 200 500 1k 2k 5k Respons...

Page 44: ...2 1 ISO standard sets rms of vibration velocity as evaluation criteria of the vibration velocity which is also known as vibration severity EQP Equivalent peak Giving that a measuring data set is sinus...