10.1 Storing of images

A frozen image can be stored in the memory of the device by 
clicking Store image. 

A live image can also be stored in the memory of the device. The 
button “Store image” will appear underneath the live B menu when 
clicking here. Press Store image to store.   

“Store image” is active both in live and Freeze modes.  

The selection of storing format (bmp, jpg.dcm) is made in the 
Setting menu.

By default, the raw data (env) is always stored.

If an image is stored when a patient file is open without 
examination, the image will be stored in the patient file “Image 
& clips without report”. If a patient file is open in examination, the 
image will be stored in the report patient file.

If no patient file is open, the image will be stored in the list of 
unattached images.

10.2 Storing of clips

A frozen sequence can be stored in the memory of the device by 
clicking Store clip. 

“Store clip” is active in Freeze mode.

By default, the raw data (env) is always stored.

The storing of a clip can also be made in avi format or dicom 
format (DCM) if these formats have been selected in the Setting 
menu. 

If a sequence is stored when a patient file is open, the sequence 
will be stored in the patient file, in examination folder (see Storing 
Image) or miscellaneous folder.

If no patient file is open, the sequence will be stored in the list of 
unattached clips.

It is possible to select the time length of the cineloop before saving 
it in the advanced B adjustment menu (see cineloop). You can also 
select the area selection of the cineloop that should be saved (see 
cineloop). 

10.3 Review

All images and sequences stored in the memory of ExaPad can be 
reviewed and post-processed. 

Unattached Files: Images saved without a patient folder will be 
saved here. Click on ‘Clips’ or ‘Images to see details

List Of Images: The naming convention of the images or 
cineloops is as follows;

C-26112019(2).cineloop – Cineloop, 2nd clip of day on the 
26/11/19

I-26112019(3).image – Image, 3rd image of day on 26/11/19

10. Storing of images and clips, Review

Review 

and post-

process all 

images and 

sequences 

stored in the 

memory of 

the ExaPad

Review 

All images and sequences stored in the memory of ExaPad can be reviewed and post-processed.  
 

 

   

 

**POINT TO REVIEW ON THE LEFT-HAND SIDE IMAGE** 
Review and post-process all images and sequences stored in the memory of the ExaPad 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
**POINT TO UNATTACHED FILES UNDER IMAGES/CLIPS** 
Images saved without a patient folder will be saved here. Click on ‘Clips’ or ‘Images to see 
details 

 
**POINT TO THE LIST OF IMAGES** 
 The naming convention of the images or cineloops is as follows; 
 

Sorcha Stephens 5/6/2019 16:02

Comment [43]: 

Review 

1

2

1

2

Summary of Contents for EXAPad

Page 1: ...Your complete animal imaging solution Instruction manual...

Page 2: ...Mode imaging 8 M Mode Imaging 9 Freeze Mode and Cineloop 10 Storing of images and clips Review 11 Measurements 12 Applications and Presets 13 Patient file 14 Protocols 15 Report 16 EchoPad App 17 Per...

Page 3: ...rced shutdown should only be done when scanner is malfunctioning After 3 forced shutdown in a row a blue screen will appear If you are presented with the blue screen follow the on screen instructions...

Page 4: ...ce aPad scanner turns on in B imaging mode with a screen display as below ss to the controls of the scanner an access the available imaging modes by clicking on the corresponding mode Power M mic M PW...

Page 5: ...ENCE CORRESPONDS TO Enter the hospital or clinic name ce of language for the interface and keyboard of a user name new user who can have individual presets Go to the Field User and type the users by c...

Page 6: ...for better definition Close menu after Set time to close menu on left and right side of the screen 5 to 15 seconds 3 6 Image Clips Menu As default images and clips are saved as raw data 3 7 Voice rec...

Page 7: ...ps to the server during and at the end of an exam Connection parameters must be entered correctly otherwise images and clips will be stored locally When Dicom Print is activated images are printed thr...

Page 8: ...ide what measurements and tables should be used by creating a User Protocol First select the specie for which you are creating the Protocol then select an application from the list For each applicatio...

Page 9: ...utton Focus The position of the focal point on screen is adjusted by the Focus button The updated position of focus is displayed on the focus button Dynamic Increase and decrease dynamic range The upd...

Page 10: ...g System The following controls are available for voice control Deeper Increase of exploration depth Shallower Decrease of exploration depth Focus down Deeper Focus Focus up More superficial Focus Fre...

Page 11: ...ctivation increases resolution 5 CFM Mode imaging The colour scale which is also the PRF scale is graduated in two parts in order to distinguish the two directions of the flows towards and away from t...

Page 12: ...n for PW Different scale from general gain which is digital gain Audio Adjust audio level Power Adjust PW power Wall Filter Adjust wall filter This filter is filtering low frequencies linked to vascul...

Page 13: ...two different modes one in Power Doppler mode and one in B mode r Mode imaging OWER AT BOTTOM OF SCREEN wer image added to the B image HE BLUE ICONS ON LEFT HAND SIDE OF SCREEN s for adjusting Power M...

Page 14: ...Mode imaging on page 9 8 M Mode Imaging To activate M mode imaging by sliding along on the lower menu and pressing M The TM spectrum is added to the B image Position and size of the Anatomic M line P...

Page 15: ...ual www imv imaging com 15 8 3 Time scale in Anatomic TM mode The adjustment of the time scale in Anatomic TM mode is made in in the advanced adjustment menu accessed by tapping at the right hand side...

Page 16: ...red marker that will be surrounded by a blue line move the red curser until the last image in the sequence you want to store plays cineloop sequence pause cineloop sequence previous image in sequence...

Page 17: ...made by the advanced adjustment menu in PW mode 9 6 Post processing in Anatomic TM mode and TM mode Functions in white are not available for Post processing Post processing in PW mode In PW mode only...

Page 18: ...xt zone surrounded by a white rectangle in order to reposition it and or modify the entered text by clicking Edit again 9 9 Annotated arrow Click on the button Arrow A caliper is displayed this will b...

Page 19: ...can be used on live or frozen images A free text can also be entered as a mark Horse For each specie and application you can edit user annotations Some factory presets will already exist Reproduction...

Page 20: ...ption Keep annotation in freeze is activated in the settings see Settings Tools 9 Freeze Mode and Cineloop Long press on a frozen image to access list of predefined annotations Select annotation If an...

Page 21: ...ent file is open the sequence will be stored in the patient file in examination folder see Storing Image or miscellaneous folder If no patient file is open the sequence will be stored in the list of u...

Page 22: ...patient folder select the patient then press delete all Press ok to confirm delete 10 5 Loading of images or clips stored during an examination 10 Storing of images and clips Review 1 2 3 4 5 6 7 8 9...

Page 23: ...BLUE IN IMAGE 1 Step 3 POINT TO THE HIGHLIGHTED IMAGES IN IMAGE 1 Step 4 POINT TO THE AREA IN IMAGE 2 Step 5 POINT TO USB IN IMAGE 3 Step 6 POINT TO EXPORT IN IMAGE 4 Step 7 Sorcha Stephens 5 6 2019 1...

Page 24: ...o Compare and select the other image you need to compare from unattached files or even images from patients When image is selected press Compare to get the 2 images at the same time 10 Storing of imag...

Page 25: ...urements in B CFM Power M Anatomic modes 11 1 1 Distance Place the first grey caliper with the touchpad in the desired place to start to measure the distance D1 Press Set The second caliper is now dis...

Page 26: ...e all When pressing Delete all all measurements are deleted without unfreezing the image 11 1 6 Measurements in post processing and saving Measurements can be made in post processing on previously sto...

Page 27: ...ight side of the screen POINT TO BLUE MEASUREMENTS IN BOTTOM RIGHT OF SCREEN Automatic measurements Automatic measurements POINT TO ORANGE MEASUREMENTS AT BOTTOM RIGHT OF SCREEN Manual measurements Ma...

Page 28: ...cond time marker The measurement indicates the time as well as the cardiac rate corresponding to the measured period 11 2 2 Speed measurement Select the measurement Speed place the first caliper with...

Page 29: ...preset is displayed in the list of user presets Only user presets can be renamed It is impossible to rename a factory preset made by IMV imaging 12 Applications and Presets o delete the last measureme...

Page 30: ...ng by pressing Enter If the preset selected for delete is loaded and in use the device will delete it and a default preset will be loaded instead Only user presets can be deleted Factory presets made...

Page 31: ...n the database can be done manually by scrolling down the patient list using the arrows or by using a filter The patients are listed alphabetically by their surnames Arrows Search for patients using f...

Page 32: ...32 13 4 Stopping an examination There are two ways to stop an examination Go to Report and click Stop Examination Go to the patient file and click Stop Exam 13 Patient file...

Page 33: ...h to add the measurement into the report For multiple protocol measurements start by selecting the wanted measurement Then make each individual measurement by selecting them one by one as indicated ab...

Page 34: ...ns 15 Report A report is always linked to a patient start an examination before creating a report The report can be accessed when the examination is in progress or stopped ay to see format shown below...

Page 35: ...of your scanner PASSWORD Enter a password it must be 8 characters long Default is 12345678 ExaPad is now ready to be connected to an iPad 16 EchoPad App 16 EchoPad App Only available on iPad only the...

Page 36: ...If the connection is not working check that the network password for the ExaPad co entered for the Ipad Open EchoPad application on the iPad the application will search for the ExaPad POINT TO EXAPAD...

Page 37: ...the ability to connect to the internet with the ExaPad or ExaPad Mini if your connection requires going through an internet browser like in a hotel for example The ExaPad and ExaPad Mini are not inst...

Page 38: ...head is still fragile and care should be taken to protect it from any knocks 18 5 Specifications Screen Size 15inch ExaPad 12 inch ExaPad Mini Weight 7 4kg ExaPad 4kg ExaPad Mini Dimensions 39x30x7cm...

Page 39: ...e IMV imaging 126 Boulevard de la R publique 16000 Angoul me France 33 4 3702 1766 france imv imaging com www imv imaging fr North America IMV imaging 2900 43rd Street NW Suite 600 Rochester MN 55901...

Page 40: ...facebook com IMVimaging twitter IMVimaging www imv imaging com info imv imaging com 44 0 1506 460023 Contact us now IMV imaging V1_03 19 Instruction manual ExaPad Your complete animal imaging solution...

Reviews: