3.3 Wiper connections
3.4 Fuse sizes
The power supply line on the circuit board in the junction box has an
integrated fuse of 2A. Each wiper outlet has an integrated fuse of 10A for 12V
systems and 6A for 24V systems, located in the junction box.
3.5 Cable sizes
Use new cables that are undamaged and of sufficient diameter. This to prevent
too much resistance for the required electrical current.
Recommended cable sizes:
Amperage
Max. length
Min. diameter
0.1 – 2.5
10 m (33“)
2.5 mm² (14 gauge)
2.6 – 4.0
10 m (33“)
4.0 mm² (12 gauge)
4.1 – 8.0
10 m (33”)
6.0 mm² (10 gauge)
W 1 W 2 W 3
W 4 W 5
Wiper 1
Wiper 2
Wiper 3
Wiper 4
Wiper 5
Pump / solenoid
Battery - B
Red
Black
Blue
Battery
12V / 24V
Red Black Yellow White
53a = Self park 53e = Common leg 31b = Negative 53 = Low speed
53b = High speed
To wiper motor
Color code and
connection of wiring
coming from the
junction box is:
*
Red
is to be
connected to the Self
Park (53a) motor wire
*
Black
is to be
connected to the
Negative (31b) and
Common Leg (53e) of
the motor wire
*
Yellow
is to be
connected to the Low
Speed (53) of the
motor wire
*
White
is to be
connected to the High
Speed (53b) of the
motor wire
Always refer to the users manual as
supplied with the Exalto wipers, before
connecting Exalto wipers to the control
panels!