MNEMONIC
FUNCTION
TYPE
EE
Encoder Enable Flag
Setup Flag
DESCRIPTION
The EE flag enables or disables the optional encoder mode of the MDrive Motion Control.
USAGE
DEFAULT
EE= <0/1>
0 (Disabled)
EXAMPLE:
EE=0
‘Disable encoder mode
EE=1
‘Enable encoder mode
RELATED COMMANDS: DB, C2, SF, SM, ST
MNEMONIC
FUNCTION
TYPE
E M
Echo Mode Flag
Setup Flag
DESCRIPTION
The Echo Mode Flag will set the full/half duplex configuration of the RS-485 channel. 0=Full Duplex (default), 1=Half Duplex.
USAGE
DEFAULT
EM= <0/1>
0 (Full Duplex)
EXAMPLE:
EM=0
‘full duplex mode
EM=1
‘half duplex mode
RELATED COMMANDS: BD
MNEMONIC
FUNCTION
TYPE
EF
Read-Only Error Flag
Status Flag
DESCRIPTION
The Error flag will indicate whether or not an error condition exists. It is automatically cleared when a new program is executed. The
only way to manually clear the EF flag is to read the value of the ER variable or set ER=0
There is an instruction, OE, which allows the user to specify the execution of a subroutine in the program memory when an error
occurs. The subroutine might contain instructions to read the ER variable which would clear the EF flag.
USAGE
RESPONSE
PR EF
0 = No Error Exists
1 = Error Condition Exists
EXAMPLE:
PR EF
‘read the state of the error flag
RELATED COMMANDS: ER, OE
Summary of Contents for 17
Page 1: ...OPERA TING INSTRUCTIONS T intelligent motion systems inc Excellence in MotionTM TM ...
Page 5: ...3 Part 1 General Information and Hardware Specifications ...
Page 6: ...4 Intentionally Left Blank ...
Page 19: ...17 Part 2 Connecting Configuring and Programming the MDrive Motion Control ...
Page 20: ...18 Intentionally Left Blank ...