41
MNEMONIC
FUNCTION
TYPE
D
Deceleration
Motion Variable
DESCRIPTION
The D variable sets the peak deceleration of the MDrive in steps per second
2
.
USAGE
UNITS
RANGE
DEFAULT
D=<decl>
Steps/sec
2
0 to 1525878997
1000000
EXAMPLE:
D=20000
‘set acceleration to 20000 step/sec
2
D=A
‘set deceleration equal to acceleration
RELATED COMMANDS: A,
MNEMONIC
FUNCTION
TYPE
DB
Set Encoder Deadband
Setup Variable
DESCRIPTION
This variable defines the + and - length of the encoder deadband in encoder counts.
When the encoder is enabled, a move is not completed until motion stops within DB.
USAGE
UNITS
RANGE
DEFAULT
DB=<counts>
Encoder Counts
0 to 65000
1
EXAMPLE:
DB=5
‘Set Encoder Deadband to ± 5 encoder counts
RELATED COMMANDS: EE
MNEMONIC
FUNCTION
TYPE
DC
Decrement Variable
Program Instruction
DESCRIPTION
The DC instruction will decrement the specified variable by one.
USAGE
DC <var>
EXAMPLE:
DC R1
‘Decrement User Register 1
RELATED COMMANDS: IC
MNEMONIC
FUNCTION
TYPE
D1-D5
Digital Input Filtering
I/O Variable
DESCRIPTION
This variable will set the digital filtering to be applied to the selected input 1 - 5. The input must be stable for “time” amount of
milliseconds before a change in state is available.
USAGE
UNITS
RANGE
D <1-5>=<time>
Milliseconds
0 to 255
EXAMPLE:
D1=0
‘no debounce
D4=150
‘150 mSec of filtering
RELATED COMMANDS: I1-I5
Summary of Contents for 17
Page 1: ...OPERA TING INSTRUCTIONS T intelligent motion systems inc Excellence in MotionTM TM ...
Page 5: ...3 Part 1 General Information and Hardware Specifications ...
Page 6: ...4 Intentionally Left Blank ...
Page 19: ...17 Part 2 Connecting Configuring and Programming the MDrive Motion Control ...
Page 20: ...18 Intentionally Left Blank ...