32
PLASMA CUTTER 85A / 125A
EN
ANOMALIES, SOLUTIONS
PROBLEMS
SOLUTIONS
The machine does not switch on.
- Check that the power cord is plugged to the mains properly.
- Check that the device is powered on the main circuit breaker panel or
power supply box .
- Check that the voltage is not too low (More than 15% below nominal
voltage).
- Check that the circuit breaker didn't activate.
The pilot arc switches off
- Worn consumables
- No electrical contact between the tailpipe and the electrode.
The cutting arc stops.
- Cutting speed is too low.
- Bad earth clamp connection.
- Cutting height too elevated
Insufficient penetration.
- Unadapted tailpipe.
- Cutting speed too fast.
- Not enough current.
- Part is too thick (more than 15 % below nominal voltage).
Consumables' early deterioration.
- Current is too high for the tailpipe.
The arc sprays and whistles.
- Purge the air filter.
- The filtering cartridge must be cleaned or replaced.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported.