Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
58
Parameter Name
Format
Description
Flash Programming
Failed |
Failed to write the flash memory.
Flash Programming
Failed |
Failed to burn the flash.
Current Image
Invalidated |
The current image has been invalidated by a previous
“fallback” command.
No Fallback Image
Available |
This reason applies to the rejection of multiple
commands following a “fallback” commands.
Generic Error >
Download error other than those specified above.
PrimaryImageType STRING
The type of image stored in the primary (currently
defaults to Linux)
PrimaryImageSystemVersion STRING
The version string of the primary image system
partition
PrimaryImageConfigVersion STRING
The version string of the primary image configuration
partition
SecondaryImageType STRING
The type of image stored in the secondary (currently
defaults to Linux)
secondaryImageSystemVersion STRING
The version string of the secondary image system
partition
secondaryImageConfigVersion STRING
The version string of the secondary image
configuration partition
Following an upgrade command, the
UpgradeStatus
can take any of the values shown in Table 8-14. For each abnormal
status, a Reason parameter is given to indicate the reason for the status. The reason values are also given in Table 8-14.