Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
31
Figure 7-3 Pull Mode Upgrade GUI Screen
7.5.3. Factory Default Restoration
The following command can be used to restore the Speedway reader's factory default configuration settings associated with the
currently running image:
•
The user can use the Rshell command
config image factory
to return the reader to a factory default configuration.
The command retains the current primary SOP, but defaults the reader’s configuration and erases any custom
application. See section 8.4.2.1 for details.
7.5.4. Fallback to Previous Image
The following command can be used to fallback or restore the reader’s previous image in case something was adversely
affected by the upgrade procedure:
•
The user can invoke the Rshell command
config image fallback
to restore the reader to its previous image. See
section 8.4.2.2 for details.
7.5.5. Query the Upgrade Status
The following commands are used to query the status of upgrades including factory default and fallback:
•
The user can invoke the Rshell command
show image summary
to view the details of the current primary and
secondary images. This command also shows the status of pending and completed upgrades as well as error codes
indicating the reasons for upgrade failures. See section 8.5.2.2 for details.
•
The user can invoke the Rshell command
show image metafile
to view the details of the current retrieve mode and
metafile data. See section 8.5.2.1 for details.
7.5.6. Background Execution of Image Management Commands
Some image management commands are executed in the background and are not finished right away. If a previous image
management command is still being processed, a subsequent image management command will be rejected with a command
response code of “
Previous-Command-In-Progress
”. The following image management commands have this
behavior:
config
image
metafile
config
image
upgrade