![Imperx C4180C User Manual Download Page 54](http://html1.mh-extra.com/html/imperx/c4180c/c4180c_user-manual_2048993054.webp)
Cheetah Python Camera with USB3 Interface
–
User Manual
December 5, 2017
Page
54
of
78
Rev 1.0
4.7.9 Strobe Controls
These registers enable and control the two available strobes. Strobe signals map to one or
both of the available strobe outputs (5.6 Strobes).
Figure 25: Strobe parameters.
The following descriptions apply equally to Output 1 (OUT1) and Output 2 (OUT2) and
Strobe1 and Strobe2.
OUT1Polarity / OUT2Polarity
: Sets the OUT1 or OUT2 active logic level to either Active
Low or Active High.
OUT1Selector / OUT2Selector
: Maps the
camera’s
internal signals: Trigger, Pulse
Generator, Strobe 1 or Strobe 2 to OUT1 or OUT2 camera output.
Strobe1Mode / Strobe2Mode
: Enables or disables the strobe.
Strobe1Reference / Strobe2Reference
: Sets the reference for the strobe to either the
start of exposure or start of image readout.
Strobe1Width / Strobe2Width
: Sets the strobe pulse duration in microseconds.
Strobe1Delay / Strobe2Delay
: Sets the strobe delay from the selected Reference in
microseconds.
4.7.10 Pulse Generator Controls
The Pulse Generator provides c
ontrol over the camera’s internal pulse for generating
trigger or output signals (5.9 Pulse Generator).