Installation
Heat Pumps & Solar Thermal – Legionella Control
Heat pumps often need to use the immersion heater to get the hot
water to a high temperature for the purpose of Legionella control.
This is an ideal application for the
External Boost
input.
The immersion heater should ONLY be connected to the immerSUN, do
not connect the immersion heater to the heat pump or solar thermal
controller.
ON/OFF Control of Other Appliances
Only resistive loads (e.g. heaters) can be connected to the variable
power Heater 1 and Heater 2 outputs. However, it is possible to simply
switch ON/OFF other types of devices by using the
Threshold
option of
the
Multifunction Relay
.
Cylinder Destratification
The effective capacity of a hot water cylinder with a top mounting
immersion can be increased by pumping the hot water to the bottom of
the cylinder, therefore allowing the immersion heater to heat the top
section of the cylinder again. The
Multifunction Relay
has a
De-strat
Pump
control option for this purpose.
Check Pack
Contents
Select suitable
Location
Mount Unit
Install Sensor
Switch ON
Complete Setup
Change Settings
if required
Make Electrical
Connections
Select Wiring
Diagram
START
FINISH
p17
p17
p25
p22
p23
p24
p12
Summary of Contents for automatic power controller
Page 1: ...1 ENGLISH Installation User Guide V1 2...
Page 11: ...11 Advanced options...
Page 24: ...Setup...
Page 25: ...25 Wiring diagrams...
Page 36: ...36 Wiring Dual Tariff Single Meter...
Page 44: ...44 4eco Ltd Church View Business Park Binbrook Lincolnshire LN8 6BY England 44 0 1472 398838...