7
STVZ1I ed 10/09
VICTRIX Zeus 1 I
Technical Documentation
Technical Documentation
Boiler pump (1).
Operates on the primary circuit return immediately after the
3-way valve to which it is connected. It is part of the integrated
multifunction unit realised in composite material.
There is a seat on the body where the automatic air vent valve
(2) is housed.
Primary heat exchanger
(condensation module).
It is formed from a casing that contains 4 elements with a
coil shape.
Each element is made up from 5 elliptical spirals (3).
The entire module is realised in stainless steel and its internal
part makes up the sealed combustion chamber and the con-
densation chamber (2).
The first three elements are affected directly by the action of
the cylindrical burner applied to the front, while the fourth is
arranged in the condensation chamber, which is separated from
the combustion chamber by sheet steel (see flue circuit).
PTo reduce head losses to a minimum and increase the flow rate
available to the system, the flow is made up from the parallel
connection of the first two elements, the return, instead is made
up from the parallel connection of the last two elements.
The heat exchanger inlet is connected to the pump flow and the
outlet, on which the NTC central heating probe is positioned
(1), is connected to the primary circuit flow.
The primary circuit return and flow pipes are coupled using
threaded fittings with flat gasket.
The flue hood (4) is connected to the rear using a relevant
gasket blocked by a metal ring.
The condensate drain is also found in the lower part.
To ease the escape of any air bubbles still present in the coils,
there is a manual air vent in the upper part of the module
(5).
FLUE GAS
RETURN
FLOW
EXHAUST
CONDENSATE
2
1
4
3
5
1
2