25
STVZ1I ed 10/09
VICTRIX Zeus 1 I
Technical Documentation
Technical Documentation
Electric circuit
The electric circuit of the VICTRIX Zeus 1I is completely
interlocked to a P.C.B. with integrated microprocessor, which
controls the functions of the generator.
The control and safety devices partly operate at network voltage
(230 V AC) and partly at low voltage.
Key:
A4
- Display board
B1
- Flow probe
B2
- Domestic hot water probe
B4
- External probe (optional)
CAR
- Comando Amico Remoto remote control (optional)
CZ
- Zones control unit (optional)
E1
- Ignition electrodes
E2
- Detection electrode
E4
- Safety thermostat
E6
- Flue safety thermostat
F1
- Phase fuse
F2
- Transformer fuse
G2
- Igniter
M1
- Boiler pump
M20
- Fan
M30
- Three-way valve
S2
- Selector switch functioning
S5
- System pressure switch
S7
- Central heating timer selector switch
S9
- Domestic hot water mode selector switch
S10
- Pump mode selector switch
S13
- Central heating temperature range selector switch
S20
- Room thermostat (optional)
T2
- Low voltage transformer
X40
- Room thermostat jumper
Y1
- Gas valve
O
range
O
range
O
range
White
White
White
Blue
Red
Black
O
range
G
reen
White
Br
own
Blue
White
Black
Black
Black
Red
Red
G
rey
G
rey
ONE RELAY BOARD
(Optional)
Br
own
Blue
Blue
Blue
G
rey
Black
Orange
Orange
Black
Black
Black- (common)
Red- (DHW
)
White- (CH)
Br
own
Black
Anti-freeze
kit
FAN
SPEED
230 Vac 50
Hz
power supply
Red
Red
White O
range
G
rey
ZONES CONTROL UNIT