BPGS PNEUMATIC GRIPPER SYSTEM
User Manual
BIM-BPGSM-0519 Rev 1 | For Technical Assistance: 800-442-4622
10
Gripper
Throat Depth
Inch (mm)
Flange Height
Inch (mm)
Working Pressure
Double Sided Grip
Force Up To
Actuation Time
BPGS10C
.76 19.3
1.27 (32.3)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa)
.050±.010 sec close /
<.090 sec open
BPGS10D
.76 19.3
1.27 (32.3)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa)
.050±.010 sec close /
<.090 sec open
BPGS10E
.76 19.3
1.27 (32.3)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa))
.050±.010 sec close /
<.090 sec open
BPGS10F
.92 23.4
1.21 (30.6mm)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa)
.050±.010 sec close /
<.090 sec open
BPGS10R
.75 19
1.03 (26.3mm)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa)
.050±.010 sec close /
<.090 sec open
BPGS10S
.76 19.3
1.27 (32.3)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa)
050±.010 sec close /
<.090 sec open
BPGS10T
.76 19.3
1.27 (32.3)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa)
.050±.010 sec close /
<.090 sec open
BPGS10U
.76 19.3
1.27 (32.3)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa)
.050±.010 sec close /
<.090 sec open
BPGS10V
.76 19.3
1.27 (32.3)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa)
.050±.010 sec close /
<.090 sec open
BPGS10W
.76 19.3
1.27 (32.3)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa)
.050±.010 sec close /
<.090 sec open
BPGS10Y
.76 19.3
1.27 (32.3)
60 psi (413kPa) Min. –
100 psi (689 kPa) Max.
450lbs (200kgf) @ 80
psi (551kPa)
.050±.010 sec close /
<.090 sec open
CLEANING AND MAINTENANCE
1) Remove excess grease from outer surfaces of gripper.
2) No required maintenance.
QUALITY ASSURANCE REQUIREMENTS
1) Verify that jaws shall open freely. Look for any irregular movement, binding, or interference.
SPECIFICATIONS
3. Apply Red Loctite 262 or equivalent to sensor stud, place thru jaw and tighten sensor nut to 72in-lb.
Cable should follow
the contour of the
gripper jaw
Cable storage loop
can be adjusted with
a push/pull motion to
provide more or less
cable slack in gripper
jaw area