PORT SIZE AND OPERATION
Gripper open
Gripper close letter “C” to identify part
1. Ports are available in 1/8" NPS or 1/8 Rc.
GRIPPER UNLOCK
1. Release jaw by using a hex key or flat screwdriver and pushing on drive pin through slot in side plate
JAW REMOVAL
1. Unlock gripper as shown in step above and remove pad(s) from existing jaws. Set a side for reassembly.
2. Top jaw should always be removed first. Remove Socket Head Cap Screw (SHCS) from side plate or indirect
sensor. Rotate side plate/sensor up to about 45° and remove side plate/sensor from gripper. Set SHCS and
Side Plate/Sensor aside for re-assembly. Remove bumper from gripper.
3. Remove jaw from gripper and flip gripper over to remove other jaw