Setting into Operation

4.1 Mounting

G

Always place the unit so that during operation a
sufficient air circulation is ensured. The air vents
at the housing must not be covered in any case.

G

The minimum distance to materials sensitive to
heat should be 50 cm.

The PARL-40SET is provided for mounting onto a
lighting stand with a standard tube diameter of
35 mm (e. g. PAST-400/SW from “img Stage Line”).
For this purpose place the stand sleeve (8) onto the
lighting stand and secure it with the screw.

IMPORTANT!

The stand must be set up in a sta-

ble way. Check all setscrews and tighten them, if
required.

To align the spotlights (11), release the respective
setscrew [hexagon socket srew] (9) and turn and
incline the spotlight into the desired direction. Make
sure that the cable (7) will not be stretched or
squeezed. Then retighten the screw. If the spotlight
should not keep its adjusted inclination, retighten
the two screws (10).

4.2 Connecting the DMX light controller

The unit may be operated via a universal light con-
troller with DMX512 protocol (e. g. DMX-1440 or
DMX-510USB from “img Stage Line”) or via the
compact LED-4MC.

For the DMX connection 3-pole XLR jacks with

the following contact configuration are available:

pin 1 = ground, 2 = DMX-, 3 = DMX+

For connection, special cables for high data flow
should be used. Standard microphone cables with
screening and a minimum cross section of 2 ×
0.22 mm

2

and with a capacity as low as possible

can only be recommended for a total cable length
of up to 100 m. For cable lengths exceeding 150 m
it is recommended to insert a DMX level matching
amplifier (e. g. SR-103DMX from “img Stage Line”).

1) Connect the DMX input (6) to the DMX output of

the light controller.

2) Connect the DMX output (5) to the DMX input of

the following light effect unit; connect its output
again to the input of the following unit, etc. until
all light effect units have been connected in a
chain.

3) Terminate the DMX output of the last DMX unit

in the chain with a 120 Ω resistor (> 0.3 W): Con-
nect a corresponding terminating plug (e. g.
DLT-123 from “img Stage Line”) to the jack.

4.3 Power supply

Connect the supplied mains cable to the mains jack
(1) first and then to a socket (230 V~ / 50 Hz). Then
the unit is ready for operation and can be operated
via a DMX light controller. To switch off, disconnect
the mains plug from the socket.

Caution:

The unit must not be connected to the

mains voltage via a dimmer!

For a more convenient operation it is recom-
mended to connect the unit to a socket which can
be switched on and off via a light switch.

4.4 Adjusting the DMX start address

To be able to operate the set of spotlights with a
light controller, its DMX start address has to be
adjusted. For this purpose use the buttons UP and
DOWN (4). The display (3) always shows the start
address and the spotlight assignment (“d” or “dr”)
alternately. After approx. 3 s, a change of the start
address will be effective automatically. 

If e. g. the addresses 10 to 25 on the DMX con-

troller are provided to control the 16 channels of the
set of spotlights, adjust the start address 10 on the
PARL-40SET.

To control the set of spotlights via the LED-4MC,

adjust start address 1.

5

Operation

5.1 Changing the spotlight assignment

To be able to control two PARL-40SET units via the
same DMX channels e. g. when using them in a
mirror-inverted way on the left and right of a stage,
the assignment of the individual spotlights to the
control channels can be reversed.

Select the desired assignment with the button

MODE (2). If the display (3) shows “d”, the follow-
ing channel assignment will apply:

channels 1 to 4:

first spotlight (from the left)

channels 5 to 8:

second spotlight

channels 9 to 12:

third spotlight

channels 13 to 16: fourth spotlight

WARNING

Never look directly into the LEDs;
this may cause eye damage.
Please note that fast changes in
lighting, e. g. flashing light, may trig-
ger epileptic seizures with photosen-
sitive persons or persons with
epilepsy!

8

GB

Summary of Contents for PARL- 40 SET

Page 1: ...SO MANUAL DE INSTRUCCIONES INSTRUKCJA OBS UGI VEILIGHEIDSVOORSCHRIFTEN SIKKERHEDSOPLYSNINGER S KERHETSF RESKRIFTER TURVALLISUUDESTA DMX LED SCHEINWERFER SET SET OF DMX LED SPOTLIGHTS SET DE PROJECTEUR...

Page 2: ...2 11 11 1 2 3 4 5 6 7 9 8 10...

Page 3: ...pareil de dommages ventuels engendr s par une utilisation inadap t e Conservez la notice pour pouvoir vous y reporter ult rieurement La version fran aise se trouve page 10 Prima di accendere Vi auguri...

Page 4: ...Funktionsst rungen auftreten Geben Sie das Ger t in jedem Fall zur Reparatur in eine Fachwerkstatt G Ziehen Sie den Netzstecker nie am Kabel aus der Steckdose fassen Sie immer am Stecker an G Verwend...

Page 5: ...MX Ausgang 5 mit dem DMX Eingang des n chsten Lichteffektger tes verbinden Des sen Ausgang wieder mit dem Eingang des nach folgenden Ger tes verbinden usw bis alle Licht effektger te in einer Kette an...

Page 6: ...Schmutzpartikel von au en gereinigt werden Nur dann kann das Licht in maximaler Helligkeit abgestrahlt werden Zum S ubern den Netzstecker aus der Steck dose ziehen Nur ein weiches sauberes Tuch und ei...

Page 7: ...cur In any case the unit must be repaired by skilled personnel G Never pull the mains cable for disconnecting the mains plug from the mains socket always seize the plug G For cleaning only use a dry s...

Page 8: ...ts have been connected in a chain 3 Terminate the DMX output of the last DMX unit in the chain with a 120 resistor 0 3 W Con nect a corresponding terminating plug e g DLT 123 from img Stage Line to th...

Page 9: ...e housing only use a soft clean cloth Never use any fluid it may leak into the unit and cause damage 7 Specifications Light source 4 146 LEDs 40 red 68 green 38 blue diameter 10 mm beam angle 20 Power...

Page 10: ...cialis G Ne d branchez jamais l appareil en tirant sur le cordon secteur retirez toujours le cordon sec teur en tirant la fiche G Pour le nettoyage utilisez seulement un chiffon sec et doux en aucun c...

Page 11: ...la sortie DMX 5 l entr e DMX du jeu de lumi re suivant Reliez sa sortie l entr e du prochain appareil et ainsi de suite jusqu ce que tous les jeux de lumi re soient reli s dans une cha ne 3 Terminez...

Page 12: ...teur Utilisez uniquement un tissu propre et doux et un produit de nettoyage doux Essuyez puis s chez la vitre Pour nettoyer les autres l ments du bo tier uti lisez exclusivement un tissu doux et propr...

Page 13: ...arecchio non funziona correttamente Per la riparazione rivolgersi sempre ad un offi cina competente G Staccare il cavo rete afferrando la spina senza tirare il cavo G Per la pulizia usare solo un pann...

Page 14: ...l uscita DMX 5 con l ingresso DMX dell unit successiva per effetti di luce e la sua uscita con l ingresso del apparecchio a valle fin ch tutte le unit per effetti di luce sono collegate formando una...

Page 15: ...ter gente delicato Quindi asciugare i dischi Per pulire le altre parti del contenitore usare solo un panno morbido pulito Non usare in nessun caso dei liquidi che potrebbero penetrare nell ap parecchi...

Page 16: ...l cualificado puede reparar el aparato bajo cualquier circunstancia G No tire nunca del cable de corriente para desco nectar el enchufe de la toma de corriente tire siempre del enchufe G Utilice s lo...

Page 17: ...fecto de luces conecte su salida de nuevo a la entrada del siguiente aparato etc hasta que todos los efectos de luces est n conectados en cadena 3 Termine la salida DMX del ltimo aparato DMX de la cad...

Page 18: ...chufe de la toma de corriente Utilice s lo un pa o suave y limpio y un detergente no agresivo Luego seque el panel Para la limpieza de las otras partes de la car casa utilice s lo un pa o suave y limp...

Page 19: ...olony personel G Nie wolno od cza zasilania ci gn c za kabel nale y zawsze chwyta za wtyczk G Do czyszczenia u ywa suchej mi kkiej cie reczki nie stosowa rodk w chemicznych ani wody G Producent ani do...

Page 20: ...o czone 3 Na wyj cie DMX ostatniego z pod czonych paneli pod czy opornik 120 0 3 W lub u y gotowy wtyk terminuj cy np DLT 123 marki img Stage Line 4 3 Zasilanie Pod czy do czony kabel zasilaj cy do gn...

Page 21: ...j ciereczki Nie wolno u ywa wody ani adnych rodk w chemicznych kt ry mog yby dosta si do wn trza urz dzenia 7 Specyfikacja r d o wiat a 4 146 diod 40 czerwonych 68 zielo nych 38 niebieskich wielko 10...

Page 22: ...igd is 2 wanneer er een defect zou kunnen optreden nadat het apparaat bijvoorbeeld is gevallen 3 wanneer het apparaat slecht functioneert Het apparaat moet in elk geval worden hersteld door een gekwal...

Page 23: ...bt eller lignende 3 hvis der forekommer fejlfunktion Enheden skal altid repareres af autoriseret per sonel G Tag aldrig netstikket ud af stikkontakten ved at tr kke i kablet tag fat i selve stikket G...

Page 24: ...likt 3 Om andra felfunktioner uppst r Enheten skall alltid lagas av kunnig personal G Drag aldrig ur kontakten genom att dra i sladden utan ta tag i kontaktkroppen G Reng r endast med en ren och torr...

Page 25: ...ssa esiintyy toimintah iri it Kaikissa n iss tapauksissa laite tulee huollattaa valtuutetussa huollossa G l koskaan irrota virtajohtoa pistorasiasta joh dosta vet m ll G K yt puhdistamiseen pelk st n...

Page 26: ...Copyright by MONACOR INTERNATIONAL GmbH Co KG Bremen Germany All rights reserved A 1153 99 01 08 2010...

Reviews: