10
English
IMG STAGELINE) . For cable lengths exceeding 150 m,
it is generally recommended to insert a DMX level
matching amplifier (e . g . SR-103DMX) .
1) Connect the DMX INPUT (4) to the DMX output
of the light controller or to the DMX output of
another DMX-controlled unit .
2) Connect the DMX OUTPUT (6) to the DMX input
of the following DMX unit . Connect the output of
this DMX unit to the input of the following DMX
unit etc . until all DMX-controlled units have been
connected in a chain .
3) To prevent interference in signal transmission, in
case of long cables or a multitude of units con-
nected in series, terminate the DMX output of the
last DMX unit in the chain with a 120 Ω resistor
(> 0 .3 W): Connect a corresponding terminating
plug (e . g . DLT-123) to the DMX output jack .
5.3.2 Setting the DMX start address
For separate control of all DMX units connected to
the light controller, each unit must have its own start
address . Example: If the first DMX channel of the
spotlight is to be controlled by the controller via DMX
address 17, set the start address on the spotlight to
17 . All other DMX channels of the spotlight will be
automatically assigned to the following addresses
(i . e . 18 – 20 in case of start address 17) .
1) Press the button MENU repeatedly until
ap-
pears on the display .
2) Press the button ENTER . The start address adjusted
(
…
) will be indicated .
3) To set the desired address, press the buttons UP
and DOWN . Now the spotlight can be operated
with the light controller .
Notes:
1 . If the DMX control does not work, call up the menu
item
and press the button ENTER .
must ap-
pear on the display . If
appears on the display,
use the button UP or DOWN to switch to
.
2 . When the menu item
,
,
or
ap-
pears on the display and DMX signals are available
at the DMX input (4), the dot at the right end of the
display will flash .
5.3.3 DMX channels and functions
DMX
channel
DMX value
Function
1
000 – 255
dimmmer 0 %
100 %
2
000 – 255
basic brightness cool white
3
000 – 255
basic brightness warm white
4
000 – 010
stroboscope off
011 – 255
stroboscope slow
fast
➂
DMX channels
5.4 Temperature indication and
overheat control
The spotlight is equipped with an overheat control .
When the temperature inside the spotlight is too
high, the spotlight will be switched off . After cool-
ing down, the spotlight will be switched on again
automatically . To indicate the inside temperature:
1) Press the button MENU repeatedly until
appears on the display .
2) Press the button ENTER .
will appear on the
display .
3) Press the button ENTER again . The inside temper-
ature (in °C) is indicated on the display .
4) To exit the menu branch, press the button MENU .
6 Cleaning the Spotlight
Clean the plastic filter in front of the LEDs at regular
intervals or as required . This is the only way to ensure
that light will be radiated at maximum brightness .
Before cleaning, disconnect the mains plug from
the socket.
Only use a dry, soft cloth and a mild
detergent . Then carefully wipe the plastic filter dry .
For cleaning the other parts of the housing, only
use a dry, clean cloth . Never use any fluid; it may leak
into the spotlight and damage it .
7 Specifications
Data protocol: . . . . . . . . . . DMX 512
Number of DMX channels: 4
Light source: . . . . . . . . . . . white COB LED
Power consumption: . . . 100 W
Beam angle: . . . . . . . . . 60°
Colour temperature: . . . adjustable
2700 K – 5600 K
Power supply: . . . . . . . . . . 230 V/ 50 Hz
Power consumption: . . . . . 110 VA max .
Dimensions: . . . . . . . . . . .
∅
220 mm × 260 mm
Weight: . . . . . . . . . . . . . . 2 .9 kg
Subject to technical modification .
All rights reserved by MONACOR
®
INTERNATIONAL GmbH &
Co. KG. No part of this instruction manual may be reproduced
in any form or by any means for any commercial use.
Summary of Contents for PARC-64/CTW