6) Switch on the active speaker system with the mains
switch POWER (7). The power LED ON (5) lights up.
7) Adjust the volume with the control LEVEL. If the
overload LED CLIP (4) lights up, turn back the con-
trol accordingly.
5
Specifications
Frequency range: . . . . . . . . 60 – 19 000 Hz
Output power: . . . . . . . . . . . 80 W
MAX
, 50 W
RMS
SPL (1 W/1 m): . . . . . . . . . . 94 dB
Max. rated SPL: . . . . . . . . . 110 dB
Inputs
Mic: . . . . . . . . . . . . . . . . .
6 mV, XLR (bal.)
Line: . . . . . . . . . . . . . . . . 300 mV, XLR (bal.)
Output: . . . . . . . . . . . . . . . . input signal fed through;
XLR (bal.)
Power supply: . . . . . . . . . . . 230 V~/50 Hz
Power consumption: . . . . . . 100 VA
Ambient temperature: . . . . . 0 – 40 °C
Dimensions (W x H x D): . . 290 x 405 x 220 mm
Weight: . . . . . . . . . . . . . . . . 9 kg
Subject to technical modification.
CAUTION
Never adjust a very high volume.
Permanent high volumes may dam-
age your hearing! The human ear
will get accustomed to high volumes
which do not seem to be that high
after some time. Therefore, do not
further increase a high volume after
getting used to it.
GB
7
All rights reserved by MONACOR
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
be reproduced in any form or by any means for any commercial use.